Cited by 2Analog and Mixed-Signal Circuit DesignRadio Frequency Integrated Circuit DesignCCD and CMOS Imaging Sensors

A CMOS readout integrated circuit with wide dynamic range for a CNT bio-sensor array system

Lee, Hyunjoong, Lee, Hyongmin, Woo, Jong-Kwan, Kim, Sunkwon, Park, Young June, Kim, Suhwan·2011·IEEE/ACM International Symposium on Low Power Electronics and Design

Abstract

We present a sensor readout integrated circuit for the CNT bio-sensor array, the heart of which is our low-power current-input continuous-time ΔΣ modulator that is capable of dynamic range extension. Experimental results show that the prototype chip, designed and fabricated in 0.18μm CMOS process, achieves a dynamic range of 87.746dB and has a readout rate of 160kHz, which guarantees 1k sample/s per each sensor. It consumes 8.94μW/cell considering the 16×10 sensors and its core area is 0.085mm2.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/islped.2011.5993664

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 10 · Cited by 2

Authors
Lee, H., Lee, H., Woo, J.-K., Kim, S., Park, Y. J., & Kim, S.
Affiliations
Seoul National University (KR)
Venue
IEEE/ACM International Symposium on Low Power Electronics and Design
Publisher
IEEE
Published
2011-08
Volume
287
Pages
357-360
OpenAlex
W3139826458
Cited by
2
References
10
Citations by year
2016: 1 · 2012: 1
FWCI
0.68
Type
conference paper
Language
en
Open access
closed
Locations
International Symposium on Low Power Electronics and Design (ISLPED) (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
Keywords
CMOS readout circuit, carbon nanotube biosensors, biosensor arrays, continuous-time delta-sigma modulator, dynamic range extension, low-power readout, 0.18 μm CMOS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review