Evaluation of LoRa LPWAN technology for remote health and wellbeing monitoring
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Low power consumption, low transceiver chip cost and large coverage area are the main characteristics of the low power wide area networks (LPWAN) technologies. We expect that LPWAN can be part of enabling new human-centric health and wellness monitoring applications. Therefore in this work we study the indoor performance of one LPWAN technology, namely LoRa, by the means of real-life measurements. The measurements were conducted using the commercially available equipment in the main campus of the University of Oulu, Finland, which has an indoor area spanning for over 570 meters North to South and over 320 meters East to West. The measurements were executed for a sensor node operating close to human body that was periodically reporting the sensed data to a base station. The obtained results show that when using 14 dBm transmit power and the largest spreading factor of 12 for the 868 MHz ISM band, the whole campus area can be covered. Measured packet success delivery ratio was 96.7 % without acknowledgements and retransmissions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the coverage of LPWANs: range evaluation and channel attenuation model for LoRa technology
Petajajarvi, J., Mikhaylov, K., Roivainen, A., Hanninen, T., & Pettissalo, M. (2015) · 2015 14th International Conference on ITS Telecommunications (ITST) · doi:10.1109/itst.2015.7377400 · Cited by 735
Self-citation
Cited by
Low power wide area networks: an overview
Raza, U., Kulkarni, P., & Sooriyabandara, M. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2652320 · Cited by 2,047
“study [47] conducted at a university, end devices transmitted at 14 dBm using highest spreading factor (12) to the base station that was located within 420 m radius.”
BackgroundInternet-of-Things (IoT)-Based Smart Agriculture: Toward Making the Fields Talk
Ayaz, M., Ammad-Uddin, M., Sharif, Z., Mansour, A., & Aggoune, E.-H. M. (2019) · IEEE Access · doi:10.1109/access.2019.2932609 · Cited by 1,306
A Survey of LoRaWAN for IoT: From Technology to Application
Haxhibeqiri, J., De Poorter, E., Moerman, I., & Hoebeke, J. (2018) · Sensors · doi:10.3390/s18113995 · Cited by 618
Current Progress and Future Prospects of Agriculture Technology: Gateway to Sustainable Agriculture
Khan, N., Ray, R. L., Sargani, G. R., Ihtisham, M., Khayyam, M., & Ismail, S. (2021) · Sustainability · doi:10.3390/su13094883 · Cited by 510
Internet of underground things in precision agriculture: Architecture and technology aspects
Vuran, M. C., Salam, A., Wong, R., & Irmak, S. (2018) · Ad Hoc Networks · doi:10.1016/j.adhoc.2018.07.017 · Cited by 291
LoRa Scalability: A Simulation Model Based on Interference Measurements
Haxhibeqiri, J., Van den Abeele, F., Moerman, I., & Hoebeke, J. (2017) · Sensors · doi:10.3390/s17061193 · Cited by 273
Muhammed, T., Mehmood, R., Albeshri, A., & Katib, I. (2018) · IEEE Access · doi:10.1109/access.2018.2846609 · Cited by 263
Indoor deployment of low-power wide area networks (LPWAN): A LoRaWAN case study
Neumann, P., Montavont, J., & Noel, T. (2016) · 2016 IEEE 12th International Conference on Wireless and Mobile Computing, Networking and Communications (WiMob) · doi:10.1109/wimob.2016.7763213 · Cited by 184
“The authors of [10] study how LoRaWAN suits for non-line-of-sight indoor operation.”
BackgroundAnalytical and Simulation study for LoRa Modulation
Mroue, H., Nasser, A., Parrein, B., Hamrioui, S., Mona-Cruz, E., & Rouyer, G. (2018) · 2018 25th International Conference on Telecommunications (ICT) · doi:10.1109/ict.2018.8464879 · Cited by 55
A Discreet Wearable Long-Range Emergency System Based on Embedded Machine Learning
Orfanidis, C., Hassen, R. B. H., Kwiek, A., Fafoutis, X., & Jacobsson, M. (2021) · 2021 IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops) · doi:10.1109/percomworkshops51409.2021.9430981 · Cited by 14
“The advantages of using LPWAN in health and activity monitoring are that they offer high robustness and reliability and the coverage is significantly larger [24] compared to Bluetooth Low Energy (BLE) or IEEE 802.”
Background
Metadata
- Authors
- Petajajarvi, J., Mikhaylov, K., Hamalainen, M., & Iinatti, J.
- Venue
- 2016 10th International Symposium on Medical Information and Communication Technology (ISMICT)
- Publisher
- IEEE
- Published
- 2016-03
- Pages
- 1-5
- OpenAlex
- W2471815506
- Cited by
- 233
- References
- 1
- FWCI
- 53.71
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.