Towards Less Supervision in Activity Recognition from Wearable Sensors
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Activity Recognition has gained a lot of interest in recent years due to its potential and usefulness for context-aware wearable computing. However, most approaches for activity recognition rely on supervised learning techniques limiting their applicability in real-world scenarios and their scalability to large amounts of activities and training data. State-of-the-art activity recognition algorithms can roughly be divided in two groups concerning the choice of the classifier, one group using generative models and the other discriminative approaches. This paper presents a method for activity recognition which combines a generative model with a discriminative classifier in an integrated approach. The generative part of the algorithm allows to extract and learn structure in activity data without any labeling or supervision. The discriminant part then uses a small but labeled subset of the training data to train a discriminant classifier. In experiments we show that this scheme enables to attain high recognition rates even though only a subset of the training data is used for training. Also the tradeoff between labeling effort and recognition performance is analyzed and discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147 · cited 1×
“Interestingly, while there seem to be but a few types of features employed, there exists quite a range of classification methods, going from generative and probabilistic models [ 1 , 13, 20] to discriminative approaches [11, 10].”
BackgroundFine-Grained Activity Recognition by Aggregating Abstract Object Usage
Patterson, D. J., Fox, D., Kautz, H., & Philipose, M. (2005) · Ninth IEEE International Symposium on Wearable Computers (ISWC'05) · doi:10.1109/iswc.2005.22 · Cited by 452 · cited 1×
“Interestingly, while there seem to be but a few types of features employed, there exists quite a range of classification methods, going from generative and probabilistic models [1, 13 , 20] to discriminative approaches [11, 10].”
Background
Cited by
A Survey on Human Activity Recognition using Wearable Sensors
Lara, O. D., & Labrador, M. A. (2013) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2012.110112.00192 · Cited by 2,662
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
“Those schemes include, for example, k-nearest neighbor (kNN) classification [31,35], support vector machines (SVM) [36,37], Naive Bayes classifier [38,39], Gaussian mixture model (GMM) [40] and hidden Markov model (HMM) [41,42].”
MethodPhysical Human Activity Recognition Using Wearable Sensors
Attal, F., Mohammed, S., Dedabrishvili, M., Chamroukhi, F., Oukhellou, L., & Amirat, Y. (2015) · Sensors · doi:10.3390/s151229858 · Cited by 796
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Machine learning in medical applications: a review of state-of-the-art methods
Shehab, M., Abualigah, L., Shambour, Q., Abu-Hashem, M. A., Shambour, M. K. Y., Alsalibi, A. I., & Gandomi, A. H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105458 · Cited by 542
Metadata
- Authors
- Huynh, T., & Schiele, B.
- Venue
- 2006 10th IEEE International Symposium on Wearable Computers
- Publisher
- IEEE
- Published
- 2006-10
- Pages
- 3-10
- ISSN
- 1550-4816 (ISSN-L)
- OpenAlex
- W2096771210
- Cited by
- 100
- References
- 2
- FWCI
- 4.24
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.