The effect of data center temperature on energy efficiency

Patterson, Michael K.·2008·2008 11th Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems

Abstract

Server's capabilities are increasing at or beyond the rate of performance improvement gains predicted by Moore's Law for the silicon itself. The challenge for the information technology (IT) owner is housing and operating all of this computational power in the data center. With more computational power in each unit volume, the industry is experiencing a significant increase in power density and hence a greater cooling challenge. The ability to now tackle computational tasks that were previously unattainable has driven energy costs to new levels. Methods to reduce the energy used in cooling these machines are being studied throughout the industry. One of the areas being considered is increasing the data center server ambient inlet temperature. ASHRAE [1] suggests a recommended limit of 20 - 25degC for the most advanced Data Centers. There is a belief that operating at the high end of this range or above it will reduce the total power use in the data center by making the cooling system more efficient. A thermodynamic analysis clearly indicates that increasing the temperature of the high temperature heat source, while holding the lower temperature heat sink constant, will give an efficiency gain to the heat removal from the system. Unfortunately the simple model does not capture all of the components of the overall system and may lead to an erroneous conclusion. In fact, increasing the ambient temperature can lead to an increase in power usage of some components and systems in the data center as temperature goes up. The overall room energy use may only go down marginally or may even go up at warmer temperatures. In this paper we examine the complete energy picture from the utility connection to the rejection of heat from the facility to the outdoor environment and look at the impact an increased ambient temperature will have on each component in that chain. This analysis indicates that there is an optimum temperature for data center operation that will depend on each data center's individual characteristics, include IT equipment, cooling system architecture, data center location (e.g. outside ambient conditions), as well as other factors. Additional impacts of an increasing ambient inlet temperature, such as reliability issues and operational complexity are also discussed. It is concluded that simply raising the ambient temperature in the data center may not have the desired effect of energy use reduction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/itherm.2008.4544393

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 199

Metadata

Authors
Patterson, M. K.
Venue
2008 11th Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems
Publisher
IEEE
Published
2008-05
Pages
1167-1174
ISSN
1087-9870 (ISSN-L)
OpenAlex
W2075653320
Cited by
199
References
0
FWCI
3.15
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of data center temperature on energy efficiency. https://app.cochat.ai/papers/10.1109/itherm.2008.4544393
The paper
Patterson, M. K. (2008). The effect of data center temperature on energy efficiency. 2008 11th Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems. https://doi.org/10.1109/itherm.2008.4544393

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.