Evaluation of RU-Netra ¿ Tactile Feedback Navigation System For The Visually Impaired
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An evaluation of novel tactile navigation system for the blind is described in this paper. The handle processes ultrasonic sensor signals and conveys information to the user through variable and synchronized vibrations, which will enhance the sense of orientation and distance for the user. Various tactile perception patterns are used to convey information to the user using sensitivity of the hand. These schemes give feedback to the user using various vibrating patterns which are dependent on three parameters namely intensity of vibration, location of the vibro-tactile actuator and the pulse duration of sensing signal. We are showing different navigation scenario results of the device on 15 sighted users of different age group, genders and hand sizes by making them blindfolded. The prototype has an ergonomic design, is lightweight, compact, and adjustable to different hand sizes
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Espinosa, M. A., Ungar, S., Ochaı́ta, E., Blades, M., & Spencer, C. (1998) · Journal of Environmental Psychology · doi:10.1006/jevp.1998.0097 · Cited by 168
Cited by
Wearable Obstacle Avoidance Electronic Travel Aids for Blind: A Survey
Dakopoulos, D., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2021255 · Cited by 654
Elmannai, W., & Elleithy, K. (2017) · Sensors · doi:10.3390/s17030565 · Cited by 338
Haptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“[83] created a cylindrical handheld tactile device with 4 ultrasonic sensors pointing front, left, right, and below the device held in front of the user.”
BackgroundDesigning sensory-substitution devices: Principles, pitfalls and potential1
Kristjánsson, Á., Moldoveanu, A., Jóhannesson, Ó. I., Balan, O., Spagnol, S., Valgeirsdóttir, V. V., & Unnthorsson, R. (2016) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-160647 · Cited by 116
“Koo et al. (2008) developed a vibration device for the fingertips (see also Shah et al., 2006) but such methods may fail the usability test (Dakopolous & Bourbakis, 2010).”
Method
Metadata
- Authors
- Shah, C., Bouzit, M., Youssef, M., & Vasquez, L.
- Venue
- 2006 International Workshop on Virtual Rehabilitation
- Publisher
- IEEE
- Published
- 2006
- Pages
- 72-77
- OpenAlex
- W2126673261
- Cited by
- 56
- References
- 1
- FWCI
- 3.43
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.