Design and evaluation of an intelligent remote tidal volume variability monitoring system in e-health applications
Abstract
A reliable long-term monitoring and diagnosis of breath disorders at an early stage provides an improvement of medical act, life expectancy, and quality of life while decreasing the costs of treatment and medical services. Therefore, a real-time unobtrusive monitoring of respiration patterns, as well as breath parameters, is a critical need in medical applications. In this paper, we propose an intelligent system for patient home care, capable of measuring respiration rate and tidal volume variability via a wearable sensing technology. The proposed system is designed particularly for the goal of diagnosis and treatment in patients with pathological breathing, e.g., respiratory complications after surgery or sleep disorders. The complete system was comprised of wearable calibrated accelerometer sensor, Bluetooth low energy, and cloud database. The experiments are conducted with eight subjects and the overall error in respiration rate calculation is obtained 0.29%±0.33% considering SPR-BTA spirometer as the reference. We also introduce a method for tidal volume variability estimation while validated using Pearson correlation. Furthermore, since it is essential to detect the critical events resulted from sudden rise or fall in per breath tidal volume of the patients, we provide a technique to automatically find the accurate threshold values based on each individual breath characteristics. Therefore, the system is able to detect the major changes, precisely by more than 98%, and p…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
BLE can be a more suitable wireless protocol than ZigBee and low-power Wi-Fi for multi-sensor wearable bioelectric signal acquisition systems.
“Compared with ZigBee and low-power Wi-Fi, Bluetooth Low Energy (BLE) can be a more suitable wireless protocol for such systems.”
From Comparison between Two Time Synchronization and Data Alignment Methods for Multi-Channel Wearable Biosensor Systems Using BLE Protocol (2023) · cites this paper as [19]
BLE has lower power consumption (~1 mA) and a high transmission speed (2 Mbps) compared with low-power Wi-Fi.
“Compared with low-power Wi-Fi, BLE has lower power consumption of ~1 mA and a high transmission speed of 2 Mbps [17,18,19].”
From Comparison between Two Time Synchronization and Data Alignment Methods for Multi-Channel Wearable Biosensor Systems Using BLE Protocol (2023) · cites this paper as [19]
Cites
Feiner, J. R., Severinghaus, J. W., & Bickler, P. E. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000285988.35174.d9 · Cited by 400 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A Continuous Respiratory Monitoring System Using Ultrasound Piezo Transducer
Shahshahani, A., Bhadra, S., & Zilic, Z. (2018) · 2018 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2018.8351359 · Cited by 19 · see citing works
Self-citationWang, H., Li, J., McDonald, B. E., Farrell, T. R., Huang, X., & Clancy, E. A. (2023) · Sensors · doi:10.3390/s23052465 · Cited by 18 · see citing works
- Authors
- Fekr, A. R., Radecka, K., & Zilic, Z.
- Affiliations
- McGill University (CA)
- ORCID
- Fekr, Atena Roshan
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2015-09
- Volume
- 19
- Issue
- 5
- Pages
- 1532-1548
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1554242441
- Cited by
- 61
- References
- 1
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 9 · 2022: 11 · 2021: 6 · 2020: 5 · 2019: 7 · 2018: 7 · 2017: 5 · 2016: 5 · 2015: 1
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Biomedical and Health Informatics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- tidal volume variability, respiration rate monitoring, wearable sensors, accelerometer, Bluetooth Low Energy, cloud databases, home care, sleep disorders, postoperative pulmonary complications, threshold detection, alarm system, e-health
- MeSH terms
- Adolescent, Adult, Algorithms, Female, Humans, Male, Medical Informatics, Middle Aged, Signal Processing, Computer-Assisted, Tidal Volume, Telemedicine, Young Adult, Remote Sensing Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review