Prediction of Freezing of Gait in Parkinson's From Physiological Wearables: An Exploratory Study
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Freezing of gait (FoG) is a common gait impairment among patients with advanced Parkinson's disease. FoG is associated with falls and negatively impacts the patient's quality of life. Wearable systems that detect FoG in real time have been developed to help patients resume walking by means of rhythmic cueing. Current methods focus on detection, which require FoG events to happen first, while their prediction opens the road to preemptive cueing, which might help subjects to avoid freeze altogether. We analyzed electrocardiography (ECG) and skin-conductance (SC) data from 11 subjects who experience FoG in daily life, and found statistically significant changes in ECG and SC data just before the FoG episodes, compared to normal walking. Based on these findings, we developed an anomaly-based algorithm for predicting gait freeze from relevant SC features. We were able to predict 71.3% from 184 FoG with an average of 4.2 s before a freeze episode happened. Our findings enable the possibility of wearable systems, which predict with few seconds before an upcoming FoG from SC, and start external cues to help the user avoid the gait freeze.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goetz, C. G., Tilley, B. C., Shaftman, S. R., Stebbins, G. T., Fahn, S., Martinez‐Martin, P., Poewe, W., Sampaio, C., Stern, M. B., Dodel, R., et al. (2008) · Movement Disorders · doi:10.1002/mds.22340 · Cited by 7,536
Cueing training in the home improves gait-related mobility in Parkinson's disease: the RESCUE trial
Nieuwboer, A., Kwakkel, G., Rochester, L., Jones, D., van Wegen, E., Willems, A. M., Chavret, F., Hetherington, V, Baker, K., & Lim, I. (2007) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.200x.097923 · Cited by 857
Discriminating Stress From Cognitive Load Using a Wearable EDA Device
Setz, C., Arnrich, B., Schumm, J., La Marca, R., Troster, G., & Ehlert, U. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036164 · Cited by 742 · cited 1×
“Similarly, wearable electrodermal activity sensors are useful in recognizing stress or other emotions [35], and for daily-life monitoring of bipolar disorder [17].”
BackgroundWearable Assistant for Parkinson’s Disease Patients With the Freezing of Gait Symptom
Bachlin, M., Plotnik, M., Roggen, D., Maidan, I., Hausdorff, J. M., Giladi, N., & Troster, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036165 · Cited by 693
Self-citation
Cited by
Gait impairments in Parkinson’s disease
Mirelman, A., Bonato, P., Camicioli, R., Ellis, T. D., Giladi, N., Hamilton, J. L., Hass, C. J., Hausdorff, J. M., Pelosin, E., & Almeida, Q. J. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30044-4 · Cited by 821
Self-citationTechnology in Parkinson’s disease: challenges and opportunities
Espay, A. J., Bonato, P., Nahab, F. B., Maetzler, W., Dean, J. M., Klucken, J., Eskofier, B. M., Merola, A., Horak, F., Lang, A. E., et al. (2016) · Movement Disorders · doi:10.1002/mds.26642 · Cited by 654
Self-citationHow Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 426
Rodríguez-Martín, D., Samà, A., Pérez-López, C., Català, A., Moreno Arostegui, J. M., Cabestany, J., Bayés, À., Alcaine, S., Mestre, B., Prats, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171764 · Cited by 237
Camps, J., Samà, A., Martín, M., Rodríguez-Martín, D., Pérez-López, C., Moreno Arostegui, J. M., Cabestany, J., Català, A., Alcaine, S., Mestre, B., et al. (2018) · Knowledge-Based Systems · doi:10.1016/j.knosys.2017.10.017 · Cited by 224
Metadata
- Authors
- Mazilu, S., Calatroni, A., Gazit, E., Mirelman, A., Hausdorff, J. M., & Troster, G.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2015-11
- Volume
- 19
- Issue
- 6
- Pages
- 1843-1854
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1920394150
- Cited by
- 146
- References
- 4
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prediction of Freezing of Gait in Parkinson's From Physiological Wearables: An Exploratory Study. https://app.cochat.ai/papers/10.1109/jbhi.2015.2465134
- The paper
- Mazilu, S., Calatroni, A., Gazit, E., Mirelman, A., Hausdorff, J. M., & Troster, G. (2015). Prediction of Freezing of Gait in Parkinson's From Physiological Wearables: An Exploratory Study. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2015.2465134
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.