The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Classification of Perceived Mental Stress Using A Commercially Available EEG Headband
Abstract
Human stress is a serious health concern, which must be addressed with appropriate actions for a healthy society. This paper presents an experimental study to ascertain the appropriate phase, when electroencephalography (EEG) based data should be recorded for classification of perceived mental stress. The process involves data acquisition, pre-processing, feature extraction and selection, and classification. The stress level of each subject is recorded by using a standard perceived stress scale questionnaire, which is then used to label the EEG data. The data are divided into two (stressed and non-stressed) and three (non-stressed, mildly stressed, and stressed) classes. The EEG data of 28 participants are recorded using a commercially available four channel Muse EEG headband in two phases i.e., pre-activity and post-activity. Five feature groups, which include power spectral density, correlation, differential asymmetry, rational asymmetry, and power spectrum are extracted from five bands of each EEG channel. We propose a new feature selection algorithm, which selects features from appropriate EEG frequency band based on classification accuracy. Three classifiers i.e., support vector machine, the Naive Bayes, and multi-layer perceptron are used to classify stress level of the participants. It is evident from our results that EEG recording during the pre-activity phase is better for classifying the perceived stress. An accuracy of [Formula: see text] and [Formula: see text] is achieved for two- and three-class stress classification, respectively, while utilizing five groups of features from theta band. Our proposed feature selection algorithm is compared with existing algorithms and gives better classification results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perceived Stress Scale: Reliability and Validity Study in Brazil
Siqueira Reis, R., Ferreira Hino, A. A., & Romélio Rodriguez Añez, C. (2010) · Journal of Health Psychology · doi:10.1177/1359105309346343 · Cited by 698
Dieleman, G. C., Huizink, A. C., Tulen, J. H. M., Utens, E. M. W. J., Creemers, H. E., van der Ende, J., & Verhulst, F. C. (2015) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2014.09.002 · Cited by 141
Cited by
A Review on Mental Stress Assessment Methods Using EEG Signals
Katmah, R., Al-Shargie, F., Tariq, U., Babiloni, F., Al-Mughairbi, F., & Al-Nashash, H. (2021) · Sensors · doi:10.3390/s21155043 · Cited by 276
Consumer Grade EEG Measuring Sensors as Research Tools: A Review
Sawangjai, P., Hompoonsup, S., Leelaarporn, P., Kongwudhikunakorn, S., & Wilaiprasitporn, T. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2962874 · Cited by 267
Human stress classification during public speaking using physiological signals
Arsalan, A., & Majid, M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104377 · Cited by 77
Self-citation
Metadata
- Authors
- Arsalan, A., Majid, M., Butt, A. R., & Anwar, S. M.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2019-11
- Volume
- 23
- Issue
- 6
- Pages
- 2257-2264
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2953666947
- Cited by
- 198
- References
- 2
- FWCI
- 18.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Classification of Perceived Mental Stress Using A Commercially Available EEG Headband. https://app.cochat.ai/papers/10.1109/jbhi.2019.2926407
- The paper
- Arsalan, A., Majid, M., Butt, A. R., & Anwar, S. M. (2019). Classification of Perceived Mental Stress Using A Commercially Available EEG Headband. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2019.2926407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.