The DOI matches its Crossref record; the references it cites are not checked yet.
Cross-Hospital Sepsis Early Detection via Semi-Supervised Optimal Transport With Self-Paced Ensemble
Open accessAbstract
Leveraging machine learning techniques for Sepsis early detection and diagnosis has attracted increasing interest in recent years. However, most existing methods require a large amount of labeled training data, which may not be available for a target hospital that deploys a new Sepsis detection system. More seriously, as treated patients are diversified between hospitals, directly applying a model trained on other hospitals may not achieve good performance for the target hospital. To address this issue, we propose a novel semi-supervised transfer learning framework based on optimal transport theory and self-paced ensemble for Sepsis early detection, called SPSSOT, which can efficiently transfer knowledge from the source hospital (with rich labeled data) to the target hospital (with scarce labeled data). Specifically, SPSSOT incorporates a new optimal transport-based semi-supervised domain adaptation component that can effectively exploit all the unlabeled data in the target hospital. Moreover, self-paced ensemble is adapted in SPSSOT to alleviate the class imbalance issue during transfer learning. In a nutshell, SPSSOT is an end-to-end transfer learning method that automatically selects suitable samples from two domains (hospitals) respectively and aligns their feature spaces. Extensive experiments on two open clinical datasets, MIMIC-III and Challenge, demonstrate that SPSSOT outperforms state-of-the-art transfer learning methods by improving 1-3% of AUC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Many studies have focused on building and externally validating ML models, but results are often mixed when these models are applied in new clinical environments [21–23].”
From Toward generalizable and interpretable machine learning models in healthcare: Insights from ICU outcome predictions (2026) · cites this paper as [23]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 67 · Cited by 20
Research works printed but not linked: 55
- 10.1109/ICDMW.2012.93 · DOI
- 10.22489/CinC.2019.238 · DOI
- 10.1109/TKDE.2009.191 · DOI · Paper page
- johnson, 2016, MIMIC-III, a freely accessible critical care database, Data Science Journal, 3, 1
- 10.1007/s41666-019-00062-3 · DOI
- chung, 0, Empirical evaluation of gated recurrent neural networks on sequence modeling, Proc NIPS Workshop Deep Learn
- choi, 0, Doctor AI: Predicting clinical events via recurrent neural networks, Proc Mach Learn Healthcare Conf, 301
- 10.1137/S0036141002410927 · DOI
- 10.1097/CCM.0000000000004550 · DOI
- gamberger, 0, Experiments with noise filtering in a medical domain, Proc Int Conf Mach Learn, 99, 143
- 10.1097/CCM.0000000000004494 · DOI
- 10.1007/978-3-319-46478-7_31 · DOI · Paper page
- pan, 2011, Domain adaptation via transfer component analysis, IEEE Trans Neural Netw, 22, 199, 10.1109/TNN.2010.2091281 · DOI
- 10.1001/jama.1990.03440210049031 · DOI
- cortes, 0, Learning bounds for importance weighting, Proc Int Conf Adv Neural Inf Process Syst, 10, 442
- azizzadenesheli, 0, Regularized learning for domain adaptation under label shifts, Proc Int Conf Learn Representations
- 10.1001/jama.2016.0288 · DOI · Paper page
- 10.1161/01.CIR.101.23.e215 · DOI · Paper page
- kumar, 0, Self-paced learning for latent variable models, Proc 23rd Int Conf Adv Neural Inf Process Syst 24th Annu Conf Neural Inf Process Syst, 1189
- freund, 0, Experiments with a new boosting algorithm, Proc Int Conf Mach Learn, 96, 148
- 10.1109/TPAMI.2016.2567393 · DOI
- 10.1007/s11263-018-1112-4 · DOI · Paper page
- elkan, 0, The foundations of cost-sensitive learning, Proc Int Joint Conf Artif Intell, 17, 973
- 10.1109/CVPR42600.2020.00445 · DOI
- 10.1613/jair.953 · DOI · Paper page
- 10.1007/978-3-540-39804-2_12 · DOI
- 10.1109/TPAMI.2018.2881114 · DOI
- futoma, 0, Learning to detect sepsis with a multitask Gaussian process RNN classifier, Proc Int Conf Mach Learn, 1174
- 10.1186/s13054-016-1596-7 · DOI
- 10.1164/rccm.201504-0781OC · DOI · Paper page
- 10.1097/01.CCM.0000217961.75225.E9 · DOI · Paper page
- damodaran, 0, DeepJDOT: Deep joint distribution optimal transport for unsupervised domain adaptation, Proc Eur Conf Comput Vis, 447
- perrot, 0, Mapping estimation for discrete optimal transport, Proc 30th Int Conf Neural Inf Process Syst, 4204
- 10.1007/978-3-662-44848-9_18 · DOI
- courty, 0, Joint distribution optimal transportation for domain adaptation, Proc Int 31st Int Conf Adv Neural Inf Process Syst, 3733
- 10.1007/978-3-319-71246-8_45 · DOI
- 10.1109/JBHI.2019.2894570 · DOI
- 10.1109/JBHI.2020.3021662 · DOI
- 10.1109/TPAMI.2016.2615921 · DOI
- 10.1097/CCM.0000000000004145 · DOI · Paper page
- 10.1097/PCC.0000000000000389 · DOI
- 10.1001/jama.2016.0287 · DOI · Paper page
- flamary, 2021, POT: Python optimal transport, J Mach Learn Res, 22, 1
- 10.24963/ijcai.2018/412 · DOI
- 10.1109/ICCV.2019.00814 · DOI
- 10.1109/ICDE48307.2020.00078 · DOI
- 10.1109/WACV51458.2022.00175 · DOI
- 10.1109/CVPR46437.2021.00116 · DOI
- yang, 0, Rethinking the value of labels for improving class-imbalanced learning, Proc 34th Int Conf Neural Inf Process Syst, 19290
- villani, 2008, Optimal Transport Old and New, 338
- 10.1109/TKDE.2018.2861006 · DOI
- 10.1109/JBHI.2019.2927463 · DOI
- maaten, 2008, Visualizing data using t-SNE, J Mach Learn Res, 9, 2579
- 10.1145/3298981 · DOI · Paper page
- 10.1145/3442381.3449855 · DOI
Metadata
- Authors
- Ding, R., Zhou, Y., Xu, J., Xie, Y., Liang, Q., Ren, H., Wang, Y., Chen, Y., Wang, L., & Huang, M.
- Affiliations
- Peking University (CN)
- Second Affiliated Hospital of Zhejiang University (CN)
- IT Center, Zhejiang University School of Medicine Second Affiliated Hospital, Hangzhou, China
- Beijing HealSci Technology Company, Ltd., Beijing, China
- Shanghai University of Finance and Economics (CN)
- ORCID
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2023-06
- Volume
- 27
- Issue
- 6
- Pages
- 3049-3060
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W4323338608
- Cited by
- 20
- References
- 67
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 3 · 2023: 2
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- Locations
- IEEE Journal of Biomedical and Health Informatics (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Natural Science Foundation of China (81801940, 6197200)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
- Physical Sciences › Computer Science › Artificial Intelligence › Domain Adaptation and Few-Shot Learning
- Keywords
- early sepsis detection, semi-supervised domain adaptation, optimal transport, class imbalance, limited labeled data, feature space alignment, MIMIC-III
- MeSH terms
- Machine Learning, Supervised Machine Learning, Algorithms, Humans, Sepsis, Early Diagnosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cross-Hospital Sepsis Early Detection via Semi-Supervised Optimal Transport With Self-Paced Ensemble. https://app.cochat.ai/papers/10.1109/jbhi.2023.3253208
- The paper
- Ding, R., Zhou, Y., Xu, J., Xie, Y., Liang, Q., Ren, H., Wang, Y., Chen, Y., Wang, L., & Huang, M. (2023). Cross-Hospital Sepsis Early Detection via Semi-Supervised Optimal Transport With Self-Paced Ensemble. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2023.3253208