The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Trends in Wind Turbine Generator Systems
Abstract
This paper reviews the trends in wind turbine generator systems. After discussing some important requirements and basic relations, it describes the currently used systems: the constant speed system with squirrel-cage induction generator, and the three variable speed systems with doubly fed induction generator (DFIG), with gearbox and fully rated converter, and direct drive (DD). Then, possible future generator systems are reviewed. Hydraulic transmissions are significantly lighter than gearboxes and enable continuously variable transmission, but their efficiency is lower. A brushless DFIG is a medium speed generator without brushes and with improved low-voltage ride-through characteristics compared with the DFIG. Magnetic pseudo DDs are smaller and lighter than DD generators, but need a sufficiently low and stable magnet price to be successful. In addition, superconducting generators can be smaller and lighter than normal DD generators, but both cost and reliability need experimental demonstration. In power electronics, there is a trend toward reliable modular multilevel topologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wind Energy Explained: Theory, Design and Application
Manwell, J. F., McGowan, J. G., & Rogers, A. L. (2009) · Wiley eBooks · doi:10.1002/9781119994367 · Cited by 3,022
A Review of the State of the Art of Power Electronics for Wind Turbines
Chen, Z., Guerrero, J. M., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2017082 · Cited by 1,487
A review of grid code technical requirements for wind farms
Tsili, M., & Papathanassiou, S. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2008.0070 · Cited by 1,373
Comparison of Direct-Drive and Geared Generator Concepts for Wind Turbines
Polinder, H., Van Der Pijl, F. F. A., De Vilder, G.-J., & Tavner, P. J. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.875476 · Cited by 1,128
Self-citationRidethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage Dip
Morren, J., & deHaan, S. W. H. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.845526 · Cited by 931
Power Electronics Converters for Wind Turbine Systems
Blaabjerg, F., Liserre, M., & Ma, K. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2181290 · Cited by 918
Overview of Multi-MW Wind Turbines and Wind Parks
Liserre, M., Cardenas, R., Molinas, M., & Rodriguez, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2103910 · Cited by 876
Overview of Control Systems for the Operation of DFIGs in Wind Energy Applications
Cardenas, R., Pena, R., Alepuz, S., & Asher, G. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2243372 · Cited by 670
Reliability of wind turbine subassemblies
Spinato, F., Tavner, P. J., van Bussel, G. J. W., & Koutoulakos, E. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2008.0060 · Cited by 646
Overview of control systems for the operation of DFIGs in wind energy applications
Pena, R., Cardenas, R., & Asher, G. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6699116 · Cited by 529
The Multilevel Modular DC Converter
Ferreira, J. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2237413 · Cited by 371
Self-citationPowering the Future of Industry: High-Power Adjustable Speed Drive Topologies
Kouro, S., Rodriguez, J., Wu, B., Bernet, S., & Perez, M. (2012) · IEEE Industry Applications Magazine · doi:10.1109/mias.2012.2192231 · Cited by 332
Review of Contemporary Wind Turbine Concepts and Their Market Penetration
Hansen, A. D., Iov, F., Blaabjerg, F., & Hansen, L. H. (2004) · Wind Engineering · doi:10.1260/0309524041590099 · Cited by 212
Offshore Wind Turbines: Reliability, availability and maintenance
Tavner, P. (2012) · Institution of Engineering and Technology eBooks · doi:10.1049/pbrn013e · Cited by 205
A Multilevel Modular Converter for a Large, Light Weight Wind Turbine Generator
Ng, C. H., Parker, M. A., Ran, L., Tavner, P. J., Bumby, J. R., & Spooner, E. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921191 · Cited by 195
Hahn, B., Durstewitz, M., & Rohrig, K. (2007) · Wind Energy · doi:10.1007/978-3-540-33866-6_62 · Cited by 188
Reliability of Wind Turbine Technology Through Time
Echavarría, E., Hahn, B., van Bussel, G. J. W., et al. (2008) · Journal of Solar Energy Engineering · doi:10.1115/1.2936235 · Cited by 152
Brisset, S., Vizireanu, D., & Brochet, P. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.921379 · Cited by 130
Power Converter Design for an Integrated Modular Motor Drive
Brown, N. R., Jahns, T. M., & Lorenz, R. D. (2007) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/07ias.2007.205 · Cited by 123
Overview of and trends in wind turbine generator systems
Polinder, H. (2011) · IEEE Power and Energy Society General Meeting (PESGM) · doi:10.1109/pes.2011.6039342 · Cited by 81
Self-citationIsidoril, A., Rossi, F. M., Blaabjerg, F., & Ma, K. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2269311 · Cited by 78
Reliability comparison of direct‐drive and geared‐drive wind turbine concepts
Arabian‐Hoseynabadi, H., Tavner, P. J., & Oraee, H. (2009) · Wind Energy · doi:10.1002/we.357 · Cited by 57
Fault tolerant generator systems for wind turbines
Polinder, H., Lendenmann, H., Chin, R., & Arshad, W. M. (2009) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2009.5075278 · Cited by 47
Self-citationA 50kW integrated fault tolerant permanent magnet machine and motor drive
Wolmarans, J. J., Gerber, M., Polinder, H., de Haan, S. W. H., Ferreira, J. A., & Clarenbach, D. (2008) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2008.4591953 · Cited by 38
Self-citationPower electronic converter systems for direct drive renewable energy applications
Chen, Z. (2013) · Elsevier eBooks · doi:10.1533/9780857097491.1.106 · Cited by 2
Cited by
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
High Performance Thermoelectric Materials: Progress and Their Applications
Yang, L., Chen, Z., Dargusch, M. S., & Zou, J. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201701797 · Cited by 958
Huang, L., Xin, H., Wang, Z., Wu, K., Wang, H., Hu, J., & Lu, C. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2740424 · Cited by 342
DC Microgrid for Wind and Solar Power Integration
Strunz, K., Abbasi, E., & Huu, D. N. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2294738 · Cited by 275
Chen, G., & Cai, X. (2018) · IEEE Access · doi:10.1109/access.2018.2789421 · Cited by 30
Metadata
- Authors
- Polinder, H., Ferreira, J. A., Jensen, B. B., Abrahamsen, A. B., Atallah, K., & McMahon, R. A.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2013-09
- Volume
- 1
- Issue
- 3
- Pages
- 174-185
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W1965065340
- Cited by
- 568
- References
- 25
- FWCI
- 25.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.