Voltage Stability and Control of Offshore Wind Farms With AC Collection and HVDC Transmission
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
This paper investigates the stability and control of offshore wind farms employing medium-voltage ac collection and high-voltage dc (HVDC) transmission to the onshore power grids. Type-IV (full power conversion) turbines and HVDC rectifier based on voltage-source converters are assumed. Output impedance models of the wind turbines and input impedance models of the HVDC rectifier in the positive- and negative-sequence are developed using the harmonic linearization method. An impedance-based stability criterion is then applied to determine the stability of the offshore ac collection bus. Possible instability of the ac bus voltage and resonance between the wind farm and the HVDC rectifier are examined through analysis of the system impedance model. The analytical impedance models are used to identify the root causes of such instability and resonance problems, and to develop possible solutions. Detailed circuit simulation is used to validate the analysis. Individual converter impedance models are also validated by experimental measurements of scaled-down prototypes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 3×
“Note that the PLL bandwidth needs to be selected also in consideration of other performances of the wind turbine inverter control [16].”
BackgroundMethodInfluentialImpedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574 · cited 5×
“To apply the stability theory presented in [8], the system is partitioned at the PCC defined above: The HVDC rectifier acts as the “grid” for the wind farm and Zr (s) is the equivalent grid impedance.”
BackgroundMethodSelf-citationDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 1×
“HVDC technology based on voltage-source converters (VSCs), including modular multilevel converters [2], avoids the need for reactive power support and also has the ability to black start the system [3].”
BackgroundImpedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167 · cited 4×
“The method has been applied to three-phase inverters connected to the grid [11] as well as LCC HVDC converter systems [12].”
BackgroundMethodSelf-citationSmall-Signal Methods for AC Distributed Power Systems–A Review
Sun, J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2029859 · Cited by 712 · cited 1×
“By applying proper modeling method, such as harmonic linearization [9], impedance models valid both below and above the fundamental frequency can be developed, thereby overcoming the other lim-”
MethodSelf-citationAdaptive Control of Grid-Connected Inverters Based on Online Grid Impedance Measurements
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2295201 · Cited by 327
Self-citationNew Breed of Network Fault-Tolerant Voltage-Source-Converter HVDC Transmission System
Adam, G. P., Ahmed, K. H., Finney, S. J., Bell, K., & Williams, B. W. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2199337 · Cited by 241 · cited 1×
“HVDC technology based on voltage-source converters (VSCs), including modular multilevel converters [2], avoids the need for reactive power support and also has the ability to black start the system [3].”
Background
Cited by
Sequence Impedance Modeling of Modular Multilevel Converters
Sun, J., & Liu, H. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2762408 · Cited by 287
Self-citationFrequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Lyu, J., Cai, X., & Molinas, M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2498182 · Cited by 267
“in [12], in which, however, the VSC-HVdc system is based on two-level converters that lack of internal dynamics, so the instability mechanism would not be able to correctly interpret the SSO phenomenon in the MMC-HVdc system with wind”
BackgroundMethod
Metadata
- Authors
- Liu, H., & Sun, J.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2014-12
- Volume
- 2
- Issue
- 4
- Pages
- 1181-1189
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2327006447
- Cited by
- 245
- References
- 8
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.