The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Optimum Number of Cascaded Cells for High-Power Medium-Voltage AC–DC Converters
Abstract
For power electronic systems to interface medium-voltage grids, e.g., in future electric ships, usually cascaded cells converters need to be employed, whereby either few cells featuring power semiconductors with high blocking voltage capability or a larger number of cells using low-voltage (LV) semiconductors can be used. As shown in this paper, physics-inspired empirical models of the dependence of Insulated-Gate Bipolar Transistor (IGBT) power modules' loss-relevant characteristics on the blocking voltage enable an analytic optimization of the efficiency of a cascaded H-bridges (ac-dc) converter, which is complemented by a full efficiency versus power density ηρ-Pareto optimization. For a 10-kV grid, 1200V or 1700V are identified as optimum blocking voltages, resulting in a suitable trade-off between efficiency and power density. Significant efficiency and power density gains can be realized by replacing silicon IGBTs by LV silicon carbide (SiC) devices in multi-cell systems, whereas single-cell designs based on high-voltage SiC devices suffer from the high dv/dt and di/dt values required to limit switching losses. Reliability is analyzed considering redundancy, showing that the reliability of designs based on lower blocking voltages can be comparable with that of designs using higher blocking voltages, and hence fewer cells, if similar effort concerning additionally installed power capability is considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Venkatachalam, K., Sullivan, C. R., Abdallah, T., & Tacca, H. (2003) · 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings. · doi:10.1109/cipe.2002.1196712 · Cited by 1,145
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Cited by
Applicability of solid-state transformers in today's and future distribution grids
Huber, J. E., & Kolar, J. W. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2738610 · Cited by 506
“A detailed analysis of such cascaded cells converter systems is given in [2], where realizations based on power semiconductors with block-”
BackgroundSelf-citation99% Efficient 10 kV SiC-Based 7 kV/400 V DC Transformer for Future Data Centers
Rothmund, D., Guillod, T., Bortis, D., & Kolar, J. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2886139 · Cited by 315
Self-citationImproving Onboard Converter Reliability for More Electric Aircraft With Lifetime-Based Control
Raveendran, V., Andresen, M., & Liserre, M. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2889626 · Cited by 91
SiC-Based Power Electronic Traction Transformer (PETT) for 3 kV DC Rail Traction
Adamowicz, M., & Szewczyk, J. (2020) · Energies · doi:10.3390/en13215573 · Cited by 24
Metadata
- Authors
- Huber, J. E., & Kolar, J. W.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2017-03
- Volume
- 5
- Issue
- 1
- Pages
- 213-232
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2517695988
- Cited by
- 191
- References
- 2
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.