The DOI matches its Crossref record.
Impedance Modeling and Stability Analysis of Grid-Connected DFIG-Based Wind Farm With a VSC-HVDC
Open accessAbstract
A new type of subsynchronous oscillation (SSO) has been observed recently in double-fed induction generator (DFIG)-based wind farm integrated via voltage source converter-based HVdc (VSC-HVdc) system. However, the mechanism of this emerging oscillation is not entirely understood. In this paper, the impedance models of DFIG with and without considering the phase-locked loop (PLL) dynamics are both derived. Then, the impedance-based simplified equivalent circuit of the multiple DFIGs interfaced with VSC-HVdc system is established. This model can be further represented as the RLC series resonance circuit to quantify the start-oscillating condition intuitively. The theoretical analysis results show that DFIGs behave as an inductance in series with a negative resistance at the resonance point, whose interaction with wind farm side VSC (WFVSC) (regard as a resistance-capacitance) constitutes an equivalent RLC resonance circuit with negative resistance. Therefore, the oscillation tends to occur due to the negative damping. In addition, the impact of various factors including number of grid-connected DFIG-wind turbines (WTs), wind speed, and parameters of PI controllers and PLL on the SSO characteristics is analyzed based on the proposed simplified model. Finally, the correctness of the theoretical analysis is validated by both the time-domain simulation and hardware-in-loop experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shi, Z., Yao, W., Li, Z., Zeng, L., Zhao, Y., Zhang, R., Tang, Y., & Wen, J. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115733 · Cited by 327
Self-citationYang, B., Zhu, T., Wang, J., Shu, H., Yu, T., Zhang, X., Yao, W., & Sun, L. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.121983 · Cited by 264
Self-citationYang, B., Wang, J., Cao, P., Zhu, T., Shu, H., Chen, J., Zhang, J., & Zhu, J. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.102572 · Cited by 152
Metadata
- Authors
- Sun, K., Yao, W., Fang, J., Ai, X., Wen, J., & Cheng, S.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2020-06
- Volume
- 8
- Issue
- 2
- Pages
- 1375-1390
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2917526305
- Cited by
- 213
- References
- 0
- FWCI
- 10.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impedance Modeling and Stability Analysis of Grid-Connected DFIG-Based Wind Farm With a VSC-HVDC. https://app.cochat.ai/papers/10.1109/jestpe.2019.2901747
- The paper
- Sun, K., Yao, W., Fang, J., Ai, X., Wen, J., & Cheng, S. (2020). Impedance Modeling and Stability Analysis of Grid-Connected DFIG-Based Wind Farm With a VSC-HVDC. IEEE Journal of Emerging and Selected Topics in Power Electronics. https://doi.org/10.1109/jestpe.2019.2901747
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.