Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record.

Micromachined acoustic resonant mass sensor

Hao Zhang, Eun Sok Kim · 2005 · Journal of Microelectromechanical Systems

Abstract

This paper describes a highly sensitive, film bulk acoustic resonator (FBAR) mass sensor (built on a micromachined silicon-nitride diaphragm with a piezoelectric thin film and Al electrodes) that can operate in vapor and liquid. The sensitivity of the device to mass change on its surface has been investigated by having various thicknesses of silicon-nitride support layer and also of Al layer. The sensor is measured to have a mass sensitivity of 726 cm/sup 2//g, which is about 50 times that of a typical quartz crystal microbalance (QCM). In vapor, the sensor (operating at around 1 GHz and having a relatively high quality (Q) factor of 200-300) shows a minimum detectable frequency shift of about 400 Hz, which corresponds to a mass change of 10/sup -9/ g/cm/sup 2/ on the sensor surface, comparable with that detectable by a QCM. In liquid, though the Q usually drops more than an order of magnitude, we obtain a Q of 40 at 2 GHz by using a second harmonic resonance of the resonator. And with the Q, a minimum 5 ppm resonant frequency shift can be detected, which corresponds to 10/sup -8/ g/cm/sup 2/ change on the sensor surface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jmems.2005.845405

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 199

Metadata

Authors
Zhang, H., & Kim, E. S.
Venue
Journal of Microelectromechanical Systems
Published
2005-08
Volume
14
Issue
4
Pages
699-706
ISSN
1057-7157 (ISSN-L)
OpenAlex
W2104545383
Cited by
199
References
0
FWCI
12.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Micromachined acoustic resonant mass sensor. https://app.cochat.ai/papers/10.1109/jmems.2005.845405
The paper
Zhang, H., & Kim, E. S. (2005). Micromachined acoustic resonant mass sensor. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2005.845405

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.