The DOI matches its Crossref record.
A Polymer-Based Flexible Tactile Sensor for Both Normal and Shear Load Detections and Its Application for Robotics
Abstract
This paper proposes and demonstrates a novel flexible tactile sensor for both normal and shear load detections. For the realization of the sensor, polyimide and polydimethylsiloxane are used as a substrate, which makes it flexible. Thin metal strain gauges, which are incorporated into the polymer, are used for measuring normal and shear loads. The salient feature of this tactile sensor is that it has no diaphragm-like structures. The unit tactile cell characteristics are evaluated against normal and shear loads. The fabricated tactile sensor can measure normal loads of up to 4 N, and the sensor output signals are saturated against loads of more than 4 N. Shear loads can be detected by different voltage drops in strain gauges. The device has no fragile structures; therefore, it can be used as a ground reaction force (GRF) sensor for balance control in humanoid robots. Four tactile unit sensors are assembled and placed in the four corners of the robots sole. By increasing bump dimensions, the tactile unit sensor can measure loads of up to 2 kgf. When loads are exerted on the sole, the GRF can be measured by these four sensors. The measured forces can be used in the balance control of biped locomotion systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Tactile sensing for dexterous in-hand manipulation in robotics—A review
Yousef, H., Boukallel, M., & Althoefer, K. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.02.038 · Cited by 784
Conductive polymer-based sensors for biomedical applications
Nambiar, S., & Yeow, J. T. W. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.046 · Cited by 513
Directions Toward Effective Utilization of Tactile Skin: A Review
Dahiya, R. S., Mittendorfer, P., Valle, M., Cheng, G., & Lumelsky, V. J. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2279056 · Cited by 428
Design and Characterization of a Soft Multi-Axis Force Sensor Using Embedded Microfluidic Channels
Vogt, D. M., Park, Y.-L., & Wood, R. J. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2272320 · Cited by 285
Metadata
- Authors
- Hwang, E.-S., Seo, J.-H., & Kim, Y.-J.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2007-06
- Volume
- 16
- Issue
- 3
- Pages
- 556-563
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W1996246968
- Cited by
- 183
- References
- 0
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Polymer-Based Flexible Tactile Sensor for Both Normal and Shear Load Detections and Its Application for Robotics. https://app.cochat.ai/papers/10.1109/jmems.2007.896716
- The paper
- Hwang, E.-S., Seo, J.-H., & Kim, Y.-J. (2007). A Polymer-Based Flexible Tactile Sensor for Both Normal and Shear Load Detections and Its Application for Robotics. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2007.896716
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.