Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Flexible Capacitive Tactile Sensor Array With Truncated Pyramids as Dielectric Layer for Three-Axis Force Measurement

Liang, Guanhao, Wang, Yancheng, Mei, Deqing, Xi, Kailun, Chen, Zichen · 2015 · Journal of Microelectromechanical Systems

Abstract

This paper presents a flexible capacitive tactile sensor array embedded with a truncated polydimethylsiloxane pyramid array as a dielectric layer. The proposed sensor array has been fabricated with 4 × 4 sensor units. The measurement ranges of forces in the x-axis, y-axis, and z-axis are 0-0.5, 0-0.5, and 0-4 N, respectively. In the range of 0-0.5 N, the sensitivities of the sensor unit are 58.3%/N, 57.4%/N, and 67.2%/N in the x-axis, y-axis, and z-axis, respectively. In the range of 0.5-4 N, the sensitivity in the z-axis is 7.7%/N. Three-axis force measurement has been conducted for all the sensor units. The average errors between the applied and calculated forces are 11.8% ± 6.4%. The sensor array has been mounted on a prosthetic hand. A paper cup and a cube are grasped by the prosthetic hand and the three-axis contact force is measured in real time by the sensor array. Results show that the sensor can capture the three-axis contact force image both in light and tight grasping. The proposed capacitive tactile sensor array can be utilized in robotics and prosthetic hand applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jmems.2015.2418095

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 187

Metadata

Authors
Liang, G., Wang, Y., Mei, D., Xi, K., & Chen, Z.
Venue
Journal of Microelectromechanical Systems
Published
2015-10
Volume
24
Issue
5
Pages
1510-1519
ISSN
  • 1057-7157 (ISSN-L)
  • 1941-0158
OpenAlex
W1964501408
Cited by
187
References
3
FWCI
6.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flexible Capacitive Tactile Sensor Array With Truncated Pyramids as Dielectric Layer for Three-Axis Force Measurement. https://app.cochat.ai/papers/10.1109/jmems.2015.2418095
The paper
Liang, G., Wang, Y., Mei, D., Xi, K., & Chen, Z. (2015). Flexible Capacitive Tactile Sensor Array With Truncated Pyramids as Dielectric Layer for Three-Axis Force Measurement. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2015.2418095

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.