The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Superconducting quantum interference devices: State of the art and applications
Abstract
Superconducting quantum interference devices (SQUIDs) are sensitive detectors of magnetic flux. A SQUID consists of a superconducting loop interrupted by either one or two Josephson junctions for the RF or dc SQUID, respectively. Low transition temperature (T/sub c/) SQUIDs are fabricated from thin films of niobium. Immersed in liquid helium at 4.2 K, their flux noise is typically 10/sup -6//spl Phi//sub 0/ Hz/sup -1/2/, where /spl Phi//sub 0//spl equiv/h/2e is the flux quantum. High-T/sub c/ SQUIDs are fabricated from thin films of YBa/sub 2/Cu/sub 3/O/sub 7-x/, and are generally operated in liquid nitrogen at 77 K. Inductively coupled to an appropriate input circuit, SQUIDs measure a variety of physical quantities, including magnetic field, magnetic field gradient, voltage, and magnetic susceptibility. Systems are available for detecting magnetic signals from the brain, measuring the magnetic susceptibility of materials and geophysical core samples, magnetocardiography and nondestructive evaluation. SQUID "microscopes" detect magnetic nanoparticles attached to pathogens in an immunoassay technique and locate faults in semiconductor packages. A SQUID amplifier with an integrated resonant microstrip is within a factor of two of the quantum limit at 0.5 GHz and will be used in a search for axions. High-resolution magnetic resonance images are obtained at frequencies of a few kilohertz with a SQUID-based detector.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Possible highT c superconductivity in the Ba?La?Cu?O system
Bednorz, J. G., & M�ller, K. A. (1986) · Zeitschrift f�r Physik B Condensed Matter · doi:10.1007/bf01303701 · Cited by 14,319
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Use of a DC SQUID receiver preamplifier in a low field MRI system
Seton, H. C., Bussell, D. M., Hutchison, J. M. S., & Lurie, D. J. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.403276 · Cited by 28
A tuned SQUID amplifier for MRI based on a DOIT flux locked loop
Seton, H. C., Hutchison, J. M. S., & Bussell, D. M. (1997) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.622015 · Cited by 26
Cited by
Nanoscale magnetic sensing with an individual electronic spin in diamond
Maze, J. R., Stanwix, P. L., Hodges, J. S., Hong, S., Taylor, J. M., Cappellaro, P., Jiang, L., Dutt, M. V. G., Togan, E., Zibrov, A. S., et al. (2008) · Nature · doi:10.1038/nature07279 · Cited by 1,984
Blümich, B., Perlo, J., & Casanova, F. (2008) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2007.10.002 · Cited by 469
The field-free Josephson diode in a van der Waals heterostructure
Wu, H., Wang, Y., Xu, Y., Sivakumar, P. K., Pasco, C., Filippozzi, U., Parkin, S. S. P., Zeng, Y.-J., McQueen, T., & Ali, M. N. (2022) · Nature · doi:10.1038/s41586-022-04504-8 · Cited by 391
SQUID-Detected in vivo MRI at Microtesla Magnetic Fields
Moszligle, M., Myers, W. R., Lee, S.-K., Kelso, N., Hatridge, M., Pines, A., & Clarke, J. (2005) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/tasc.2005.850043 · Cited by 55
Self-citation
Metadata
- Authors
- Kleiner, R., Koelle, D., Ludwig, F., & Clarke, J.
- Venue
- Proceedings of the IEEE
- Published
- 2004-10
- Volume
- 92
- Issue
- 10
- Pages
- 1534-1548
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2115373222
- Cited by
- 245
- References
- 5
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Superconducting quantum interference devices: State of the art and applications. https://app.cochat.ai/papers/10.1109/jproc.2004.833655
- The paper
- Kleiner, R., Koelle, D., Ludwig, F., & Clarke, J. (2004). Superconducting quantum interference devices: State of the art and applications. Proceedings of the IEEE. https://doi.org/10.1109/jproc.2004.833655
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.