The DOI matches its Crossref record.
Ethernet-Based Real-Time and Industrial Communications
Abstract
Despite early attempts to use Ethernet in the industrial context, only recently has it attracted a lot of attention as a support for industrial communication. A number of vendors are offering industrial communication products based on Ethernet and TCP/IP as a means to interconnect field devices to the first level of automation. Others restrict their offer to communication between automation devices such as programmable logic controllers and provide integration means to existing fieldbuses. This paper first details the requirements that an industrial network has to fulfill. It then shows how Ethernet has been enhanced to comply with the real-time requirements in particular in the industrial context. Finally, we show how the requirements that cannot be fulfilled at layer 2 of the OSI model can be addressed in the higher layers adding functionality to existing standard protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Emergence of Industrial Control Networks for Manufacturing Control, Diagnostics, and Safety Data
Moyne, J. R., & Tilbury, D. M. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2006.887325 · Cited by 272
The Tactile Internet for Industries: A Review
Aijaz, A., & Sooriyabandara, M. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2878265 · Cited by 169
Hao, W., Yang, T., & Yang, Q. (2023) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2021.3073396 · Cited by 143
Metadata
- Authors
- Decotignie, J.-D.
- Venue
- Proceedings of the IEEE
- Published
- 2005-06
- Volume
- 93
- Issue
- 6
- Pages
- 1102-1117
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2026640816
- Cited by
- 435
- References
- 0
- FWCI
- 25.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ethernet-Based Real-Time and Industrial Communications. https://app.cochat.ai/papers/10.1109/jproc.2005.849721
- The paper
- Decotignie, J.-D. (2005). Ethernet-Based Real-Time and Industrial Communications. Proceedings of the IEEE. https://doi.org/10.1109/jproc.2005.849721
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.