The DOI matches its Crossref record.
Cyber–Physical Modeling of Implantable Cardiac Medical Devices
Open accessAbstract
The design of bug-free and safe medical device software is challenging, especially in complex implantable devices that control and actuate organs in unanticipated contexts. Safety recalls of pacemakers and implantable cardioverter defibrillators between 1990 and 2000 affected over 600 000 devices. Of these, 200 000 or 41% were due to firmware issues and their effect continues to increase in frequency. There is currently no formal methodology or open experimental platform to test and verify the correct operation of medical device software within the closed-loop context of the patient. To this effect, a real-time virtual heart model (VHM) has been developed to model the electrophysiological operation of the functioning and malfunctioning (i.e., during arrhythmia) heart. By extracting the timing properties of the heart and pacemaker device, we present a methodology to construct a timed-automata model for functional and formal testing and verification of the closed-loop system. The VHM's capability of generating clinically relevant response has been validated for a variety of common arrhythmias. Based on a set of requirements, we describe a closed-loop testing environment that allows for interactive and physiologically relevant model-based test generation for basic pacemaker device operations such as maintaining the heart rate, atrial-ventricle synchrony, and complex conditions such as pacemaker-mediated tachycardia. This system is a step toward a testing and verification approach for medical cyber-physical systems with the patient in the loop.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design Techniques and Applications of Cyberphysical Systems: A Survey
Khaitan, S. K., & McCalley, J. D. (2015) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2322503 · Cited by 784
Gatouillat, A., Badr, Y., Massot, B., & Sejdic, E. (2018) · IEEE Internet of Things Journal · doi:10.1109/jiot.2018.2849014 · Cited by 429
Cloud-Supported Cyber–Physical Localization Framework for Patients Monitoring
Hossain, M. S. (2017) · IEEE Systems Journal · doi:10.1109/jsyst.2015.2470644 · Cited by 272
Review of Cyber-Physical System in Healthcare
Haque, S. A., Aziz, S. M., & Rahman, M. (2014) · International Journal of Distributed Sensor Networks · doi:10.1155/2014/217415 · Cited by 262
Credibility assessment of in silico clinical trials for medical devices
Pathmanathan, P., Aycock, K., Badal, A., Bighamian, R., Bodner, J., Craven, B. A., & Niederer, S. (2024) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1012289 · Cited by 62
Metadata
- Authors
- Jiang, Z., Pajic, M., & Mangharam, R.
- Venue
- Proceedings of the IEEE
- Published
- 2012-01
- Volume
- 100
- Issue
- 1
- Pages
- 122-137
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2081324807
- Cited by
- 172
- References
- 0
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cyber–Physical Modeling of Implantable Cardiac Medical Devices. https://app.cochat.ai/papers/10.1109/jproc.2011.2161241
- The paper
- Jiang, Z., Pajic, M., & Mangharam, R. (2012). Cyber–Physical Modeling of Implantable Cardiac Medical Devices. Proceedings of the IEEE. https://doi.org/10.1109/jproc.2011.2161241
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.