The DOI matches its Crossref record.
Fluorescence spectra from cancerous and normal human breast and lung tissues
Abstract
The fluorescence spectra have been measured from native chromophores in malignant and normal human breast and lung tissues. The spectra profiles were found to be different in both species. In addition, one normal breast tissue exhibited Raman spectra.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887
Bigio, I. J., & Mourant, J. R. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/005 · Cited by 373
Metadata
- Authors
- Alfano, R., Tang, G., Pradhan, A., Lam, W., Choy, D., & Opher, E.
- Venue
- IEEE Journal of Quantum Electronics
- Published
- 1987-10
- Volume
- 23
- Issue
- 10
- Pages
- 1806-1811
- ISSN
- 0018-9197 (ISSN-L)
- OpenAlex
- W2137304940
- Cited by
- 347
- References
- 0
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence spectra from cancerous and normal human breast and lung tissues. https://app.cochat.ai/papers/10.1109/jqe.1987.1073234
- The paper
- Alfano, R., Tang, G., Pradhan, A., Lam, W., Choy, D., & Opher, E. (1987). Fluorescence spectra from cancerous and normal human breast and lung tissues. IEEE Journal of Quantum Electronics. https://doi.org/10.1109/jqe.1987.1073234
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.