Frequency Uncertainty for Optically Referenced Femtosecond Laser Frequency Combs
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We present measurements and analysis of the currently known relative frequency uncertainty of femtosecond laser frequency combs (FLFCs) based on Kerr-lens mode-locked Ti:sapphire lasers. Broadband frequency combs generated directly from the laser oscillator, as well as octave-spanning combs generated with nonlinear optical fiber are compared. The relative frequency uncertainty introduced by an optically referenced FLFC is measured for both its optical and microwave outputs. We find that the relative frequency uncertainty of the optical and microwave outputs of the FLFC can be as low as 8times10-20and 1.7times10-18, with a confidence level of 95%, respectively. Photo-detection of the optical pulse train introduces a small amount of excess noise, which degrades the stability and subsequent relative frequency uncertainty limit of the microwave output to 2.6times10-17
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661 · cited 1×
“Moreover, the frequency-domain control of the FLFC provides access to the evolution of the carrier-envelope phase in the time domain [16], which has been the key to the recent experiments on high-field interactions that depend on the exact phase between the carrier and the envelope of few-cycle laser pulses [17], [18].”
BackgroundSelf-citationAttosecond control of electronic processes by intense light fields
Baltuška, A., Udem, T., Uiberacker, M., Hentschel, M., Goulielmakis, E., Gohle, C., Holzwarth, R., Yakovlev, V. S., Scrinzi, A., Hänsch, T. W., et al. (2003) · Nature · doi:10.1038/nature01414 · Cited by 1,653 · cited 1×
“Moreover, the frequency-domain control of the FLFC provides access to the evolution of the carrier-envelope phase in the time domain [16], which has been the key to the recent experiments on high-field interactions that depend on the exact phase between the carrier and the envelope of few-cycle laser pulses [17], [18].”
BackgroundNew Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431 · cited 1×
“The FLFC plays an increasingly important role in the comparison of laboratory-based frequency standards, enabling the measurement of fundamental physical constants in addition to searches for possible time-variations of the same [11]–[15].”
BackgroundOptical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319 · cited 3×
“Here, we expand on our earlier results [23], providing additional data that further reduce the relative uncertainty of the FLFC to 8 10 when used for optical-to-optical synthesis.”
BackgroundResultSelf-citation
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Drift-free femtosecond timing synchronization of remote optical and microwave sources
Kim, J., Cox, J. A., Chen, J., & Kärtner, F. X. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.225 · Cited by 419
Searching for dilaton dark matter with atomic clocks
Arvanitaki, A., Huang, J., & Van Tilburg, K. (2015) · Physical Review D · doi:10.1103/physrevd.91.015015 · Cited by 404
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Self-citationSpectral purity transfer between optical wavelengths at the 10−18 level
Nicolodi, D., Argence, B., Zhang, W., Le Targat, R., Santarelli, G., & Le Coq, Y. (2014) · Nature Photonics · doi:10.1038/nphoton.2013.361 · Cited by 132
Metadata
- Authors
- Ma, L.-S., Bi, Z., Bartels, A., Kim, K., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A.
- Venue
- IEEE Journal of Quantum Electronics
- Published
- 2007-02
- Volume
- 43
- Issue
- 2
- Pages
- 139-146
- ISSN
- 0018-9197 (ISSN-L)
- OpenAlex
- W2120673283
- Cited by
- 58
- References
- 4
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency Uncertainty for Optically Referenced Femtosecond Laser Frequency Combs. https://app.cochat.ai/papers/10.1109/jqe.2006.886836
- The paper
- Ma, L.-S., Bi, Z., Bartels, A., Kim, K., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2007). Frequency Uncertainty for Optically Referenced Femtosecond Laser Frequency Combs. IEEE Journal of Quantum Electronics. https://doi.org/10.1109/jqe.2006.886836
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.