A Novel Thick-Film Piezoelectric Slip Sensor for a Prosthetic Hand
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The ability to mimic the tactile feedback exhibited by the human hand in an artificial limb is considered advantageous in the automatic control of new multifunctional prosthetic hands. The role of a slip sensor in this tactile feedback is to detect object slip and thus provide information to a controller, which automatically adjusts the grip force applied to a held object to prevent it from falling. This system reduces the cognitive load experienced by the user by not having to visually assess the stability of an object, as well as giving them the confidence not to apply unnecessarily excessive grip forces. A candidate for such a sensor is a thick-film piezoelectric sensor. The method of fabricating a thick-film piezoelectric slip sensor on a prototype fingertip is described. The construction of experimental apparatus to mimic slip has been designed and analyzed to allow the coefficient of friction between the fingertip and the material in contact with the fingertip to be calculated. Finally, results show that for a coefficient of friction between the fingertip and grade P100 sandpaper of approximately 0.3, an object velocity of 0.025plusmn0.008 ms-1was reached before a slip signal from the piezoelectric sensor was able to be used to detect slip. It is anticipated that this limiting velocity will be lowered (improved) in the intended application where the sensor electronics will be powered from a battery, connections will be appropriately screened, and if necessary a filter employed. This will remove mains interference and reduce other extraneous noise sources with the consequence of an improved signal-to-noise ratio, allowing lower threshold values to be used in the detection software
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tactile sensory coding in the glabrous skin of the human hand
Johansson, R. S., & Vallbo, Å. B. (1983) · Trends in Neurosciences · doi:10.1016/0166-2236(83)90011-5 · Cited by 680 · cited 1×
“Each sensor replicates a type of sensor found in the natural human hand [20].”
Background
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Directions Toward Effective Utilization of Tactile Skin: A Review
Dahiya, R. S., Mittendorfer, P., Valle, M., Cheng, G., & Lumelsky, V. J. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2279056 · Cited by 428
Ha, M., Lim, S., Park, J., Um, D., Lee, Y., & Ko, H. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500453 · Cited by 395
Novel Tactile Sensor Technology and Smart Tactile Sensing Systems: A Review
Zou, L., Ge, C., Wang, Z., Cretu, E., & Li, X. (2017) · Sensors · doi:10.3390/s17112653 · Cited by 271
Control of prosthetic hands via the peripheral nervous system
Ciancio, A. L., Cordella, F., Barone, R., Romeo, R. A., Bellingegni, A. D., Sacchetti, R., Davalli, A., Di Pino, G., Ranieri, F., Di Lazzaro, V., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00116 · Cited by 131
Metadata
- Authors
- Cotton, D. P. J., Chappell, P. H., Cranny, A., White, N. M., & Beeby, S. P.
- Venue
- IEEE Sensors Journal
- Published
- 2007-05
- Volume
- 7
- Issue
- 5
- Pages
- 752-761
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2101552876
- Cited by
- 135
- References
- 1
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Thick-Film Piezoelectric Slip Sensor for a Prosthetic Hand. https://app.cochat.ai/papers/10.1109/jsen.2007.894912
- The paper
- Cotton, D. P. J., Chappell, P. H., Cranny, A., White, N. M., & Beeby, S. P. (2007). A Novel Thick-Film Piezoelectric Slip Sensor for a Prosthetic Hand. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2007.894912
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.