The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Design and Modeling of a Textile Pressure Sensor for Sitting Posture Classification
Abstract
A textile pressure sensor has been designed for measuring pressure distribution on the human body. Electrodes built with conductive textiles are arranged on both sides of a compressible spacer, forming a variable capacitor. The use of textiles makes unobtrusive, comfortable, lightweight, and washable sensors possible. This simplifies the goal to integrate such sensors into clothing in the future, to be simple, and fast to mount just as getting dressed. Hysteresis induced by the spacer of the sensor has been modeled with the Preisach model to reduce the measurement error from 24% to 5% on average and the maximal error from above 50% to below 10%. Standard textiles that are not specially optimized for low hysteresis can be used for designing the sensor due to the modeling. The model may also be used for other pressure or even strain sensors to reduce their hysteresis. The modeling enhances the accuracy of the textile sensor to those of commercial, nontextile pressure sensing mats. Furthermore, we used the sensor system for the classification of sitting postures in a chair. The data of nine subjects have been classified with Naive Bayes classifier, achieving an average recognition rate of 82%. We show that the textile sensor performs similarly to a commercial, nontextile pressure sensing mat for this application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Cited by
Fiber‐Based Wearable Electronics: A Review of Materials, Fabrication, Devices, and Applications
Zeng, W., Shu, L., Li, Q., Chen, S., Wang, F., & Tao, X. (2014) · Advanced Materials · doi:10.1002/adma.201400633 · Cited by 2,019
Conductive Fiber‐Based Ultrasensitive Textile Pressure Sensor for Wearable Electronics
Lee, J., Kwon, H., Seo, J., Shin, S., Koo, J. H., Pang, C., Son, S., Kim, J. H., Jang, Y. H., Kim, D. E., et al. (2015) · Advanced Materials · doi:10.1002/adma.201500009 · Cited by 1,152
Weng, W., Chen, P., He, S., Sun, X., & Peng, H. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201507333 · Cited by 577
Atalay, A., Sanchez, V., Atalay, O., Vogt, D. M., Haufe, F., Wood, R. J., & Walsh, C. J. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201700136 · Cited by 403
Hu, Q., Tang, X., & Tang, W. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2980207 · Cited by 94
Metadata
- Authors
- Meyer, J., Arnrich, B., Schumm, J., & Troster, G.
- Venue
- IEEE Sensors Journal
- Published
- 2010-08
- Volume
- 10
- Issue
- 8
- Pages
- 1391-1398
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2147376995
- Cited by
- 236
- References
- 1
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Modeling of a Textile Pressure Sensor for Sitting Posture Classification. https://app.cochat.ai/papers/10.1109/jsen.2009.2037330
- The paper
- Meyer, J., Arnrich, B., Schumm, J., & Troster, G. (2010). Design and Modeling of a Textile Pressure Sensor for Sitting Posture Classification. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2009.2037330
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.