Respiratory Monitoring System on the Basis of Capacitive Textile Force Sensors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A novel approach is presented for non-constrictive long-term-monitoring of respiration which could particularly become suitable for home care applications. The system is based on textile integrated force sensors which detect expansion of the thorax during respiration and allow wireless data transmission for maximum mobility. Possible applications include long-term monitoring of patients with chronic pulmonary diseases, early recognition of diseases and the performance measurement of athletes during exercise. Results from performance tests under various conditions are presented. The tests show a high correlation with measurements made with a flow meter as gold standard, allowing conclusions about the respiratory volume. Different respiration patterns are reliably detected and can easily be subdivided even during intensive motion of the person. The sensors' textile buildup may allow a future integration into clothing and thus a minimal constriction for the patient. Nevertheless, the respiratory volume estimations are still not accurate enough mainly because of the use of a simplified volume calculation model and the disregard of the abdominal volume changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring of Ventilation During Exercise by a Portable Respiratory Inductive Plethysmograph
Clarenbach, C. F., Senn, O., Brack, T., Kohler, M., & Bloch, K. E. (2005) · Chest · doi:10.1378/chest.128.3.1282 · Cited by 140 · cited 1×
“The most promising technique that allows to estimate breathing frequency and tidal volume is respiratory inductive plethysmography ([5], [6], [ 12 ], [16]).”
Method
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Smart fabric sensors and e-textile technologies: a review
Castano, L. M., & Flatau, A. B. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/5/053001 · Cited by 793
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
Atalay, A., Sanchez, V., Atalay, O., Vogt, D. M., Haufe, F., Wood, R. J., & Walsh, C. J. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201700136 · Cited by 403
Air-Flow-Driven Triboelectric Nanogenerators for Self-Powered Real-Time Respiratory Monitoring
Wang, M., Zhang, J., Tang, Y., Li, J., Zhang, B., Liang, E., Mao, Y., & Wang, X. (2018) · ACS Nano · doi:10.1021/acsnano.8b02562 · Cited by 287
Metadata
- Authors
- Hoffmann, T., Eilebrecht, B., & Leonhardt, S.
- Venue
- IEEE Sensors Journal
- Published
- 2011-05
- Volume
- 11
- Issue
- 5
- Pages
- 1112-1119
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2108913911
- Cited by
- 91
- References
- 1
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.