Body Sensor Network for Mobile Health Monitoring, a Diagnosis and Anticipating System
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A system capable of mobile health monitoring was designed and implemented from the first principles. The system is capable of measuring vital physiological parameters, interpret the measured signals, and provide a sense of monitoring and biofeedback to the user. In the case, a medical emergency is detected notifications are sent to a medical tedam for the analysis. The system was designed through the investigation of various biosignal extraction methods. An optical pulse oximeter sensor was designed along with the required software algorithms. The photoplethysmographic signals were extracted and used to calculate heart rate, saturation of oxygen, and pulse transits time. The pulse transit time was utilized in the estimation of continuous blood pressure measurement. The pulse oximetry implementation applies reflectance-based sensing on the user's fingertip and palm. Skin temperature is also measurable through the use of a digital temperature sensor. The system is capable of providing feedback to the user by means of a smartphone application receiving data from the device through Bluetooth. The measurement of the proposed physiological parameters were successfully measured with the appropriate degree of accuracy required by medical standards. The system is capable of health monitoring through accurate measurements, providing the user with feedback and successfully identifying medical stress resulting in the sending of a notification to a medical doctor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · cited 1×
“The PPG signal is passed through a 50 Hz notch filter in order to suppress any noise components produced by artificial light falling onto the patient’s skin or form power lines [12].”
Background
Cited by
Internet of Things for Smart Healthcare: Technologies, Challenges, and Opportunities
Baker, S. B., Xiang, W., & Atkinson, I. (2017) · IEEE Access · doi:10.1109/access.2017.2775180 · Cited by 1,130
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
“In [130], photoplethysmography signals were harvested and utilized to calculate the heart rate and oxygen saturation.”
MethodDigital Twins in Pharmaceutical and Biopharmaceutical Manufacturing: A Literature Review
Chen, Y., Yang, O., Sampat, C., Bhalode, P., Ramachandran, R., & Ierapetritou, M. (2020) · Processes · doi:10.3390/pr8091088 · Cited by 278
Virginia Anikwe, C., Friday Nweke, H., Chukwu Ikegwu, A., Adolphus Egwuonwu, C., Uchenna Onu, F., Rita Alo, U., & Wah Teh, Y. (2022) · Expert Systems with Applications · doi:10.1016/j.eswa.2022.117362 · Cited by 233
Metadata
- Authors
- Wannenburg, J., & Malekian, R.
- Venue
- IEEE Sensors Journal
- Published
- 2015-12
- Volume
- 15
- Issue
- 12
- Pages
- 6839-6852
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W1656431062
- Cited by
- 121
- References
- 1
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.