Generation of Joint Trajectories Using Hybrid Automate-Based Model: A Rocking Block-Based Approach
The DOI matches its Crossref record.
Abstract
Human walk is the combination of seven different discrete subphases. It is difficult to express the one gait cycle as a whole. To develop the human like bipedal robot, the walk cycle is divided into seven discrete subphases. Each subphases has its own continuous dynamics. To express this discrete behavior for the development of the more accurate bipedal robot, the hybrid automata are proposed. The bipedal walk is configured as the rocking block model. It is the first attempt to express the bipedal walk as a rocking block. During double support phases, it is configured as a vertical rectangular plane, and during the left and right leg swing, it is configured as the tilt of the rectangular rocking block in the left and right direction. In this paper, we have configured the bipedal robot as the rocking block before and after impact. The novelty of work is the configuration of bipedal walk as the rocking block and the development of hybrid automata. We configured the hybrid automata dynamic walk model for individual subjects. The trajectory generated by the model is compared with the two models of OpenSim bipedal Gait2354 and normal walk. This paper presents a new modeling technique of bipedal locomotion using hybrid automata. The hip, knee, and ankle trajectories have been synthesized from the model. The stability margin has been defined analytically. Similarly, these trajectories have been fed to a real humanoid robot HOAP2, which were able to perform the stable walking with these trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multi-input CNN-GRU based human activity recognition using wearable sensors
Dua, N., Singh, S. N., & Semwal, V. B. (2021) · Computing · doi:10.1007/s00607-021-00928-8 · Cited by 432
Self-citationSemwal, V. B., Gupta, A., & Lalwani, P. (2021) · The Journal of Supercomputing · doi:10.1007/s11227-021-03768-7 · Cited by 151
“It is also used for robotics walk generation and enhancing the cognitive capability to enable HRI [8, 9] and haptic [10].”
MethodSelf-citationFusion of Multi-Sensor-Based Biomechanical Gait Analysis Using Vision and Wearable Sensor
Bijalwan, V., Semwal, V. B., & Mandal, T. K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3066473 · Cited by 122
Self-citationClinical Human Gait Classification: Extreme Learning Machine Approach
Patil, P., Kumar, K. S., Gaud, N., & Semwal, V. B. (2019) · 2019 1st International Conference on Advances in Science, Engineering and Robotics Technology (ICASERT) · doi:10.1109/icasert.2019.8934463 · Cited by 97
“The analysis involves the investigating sensory motor interaction and understanding the biomechanics of locomotors system [13].”
BackgroundSelf-citationSemwal, V. B., Lalwani, P., Mishra, M. K., Bijalwan, V., & Chadha, J. S. (2021) · Computing · doi:10.1007/s00607-021-01008-7 · Cited by 55
Self-citation
Metadata
- Authors
- Semwal, V. B., & Nandi, G. C.
- Venue
- IEEE Sensors Journal
- Published
- 2016-07
- Volume
- 16
- Issue
- 14
- Pages
- 5805-5816
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2400723233
- Cited by
- 63
- References
- 0
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.