Cited by 8Analog and Mixed-Signal Circuit DesignSensor Technology and Measurement SystemsRadio Frequency Integrated Circuit Design

The DOI matches its Crossref record; the references it cites are not checked yet.

A CMOS Readout Circuit for Resistive Transducers Based on Algorithmic Resistance and Power Measurement

Open access

Abstract

This paper reports a readout circuit capable of accurately measuring not only the resistance of a resistive transducer, but also the power dissipated in it, which is a critical parameter in thermal flow sensors or thermal-conductivity sensors. A front-end circuit, integrated in a standard CMOS technology, sets the voltage drop across the transducer, and senses the resulting current via an on-chip reference resistor. The voltages across the transducer and the reference resistor are digitized by a time-multiplexed high-resolution analog-todigital converter (ADC) and post-processed to calculate resistance and power dissipation. To obtain accurate resistance and power readings, a voltage reference and a temperature-compensated reference resistor are required. An accurate voltage reference is constructed algorithmically, without relying on precision analog signal processing, by using the ADC to successively digitize the base-emitter voltages of an on-chip bipolar transistor biased at several different current levels, and then combining the results to obtain the equivalent of a precision curvature-corrected bandgap reference with a temperature coefficient of 18 ppm/°C, which is close to the state-of-the-art. We show that the same ADC readings can be used to determine die temperature, with an absolute inaccuracy of ±0.25 °C (5 samples, min-max) after a 1-point trim. This information is used to compensate for the temperature dependence of the on-chip polysilicon reference resistor, effectively providing a temperature-compensated resistance reference. With this approach, the resistance and power dissipation of a 100 Ω transducer have been measured with an inaccuracy of less than ±0.55 Ω and ±0.8%, respectively, from -40 °C to 125 °C.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jsen.2017.2764161

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

References 25 · Cited by 8

Research works printed but not linked: 27

  1. 10.1109/ISCAS.1992.230394 · DOI
  2. 10.1109/ISSCC.1964.1157541 · DOI
  3. maderbacher, 2015, A digitally assisted single-point-calibration CMOS bandgap voltage reference with a $3\sigma $ inaccuracy of ±0.08% for fuel-gauge applications, IEEE ISSCC Dig Tech Papers, 102
  4. 10.1109/JSSC.2011.2173267 · DOI
  5. 10.1109/JSSC.2011.2165235 · DOI
  6. pertijs, 2006, Precision Temperature Sensors in CMOS Technology Dordrecht, 10.1007/1-4020-5258-8 · DOI
  7. 10.1109/JSSC.2016.2639535 · DOI
  8. 10.1109/ISCAS.2008.4541641 · DOI
  9. 10.1109/ISCAS.2007.378760 · DOI
  10. 2014, AD8629 Datasheet
  11. 10.1109/JSSC.2016.2587861 · DOI
  12. 10.1109/JSSC.2013.2278737 · DOI
  13. 10.1109/TRANSDUCERS.2015.7181000 · DOI
  14. 10.1109/JSEN.2012.2192426 · DOI
  15. 10.1109/JSEN.2015.2462722 · DOI
  16. 10.1109/JSEN.2014.2307007 · DOI
  17. 10.1016/j.sna.2010.08.012 · DOI
  18. 10.1109/JSSC.2012.2218711 · DOI
  19. 10.1109/4.753676 · DOI
  20. 10.1109/JSSC.2015.2417806 · DOI
  21. 10.1109/JSSC.2007.914336 · DOI
  22. choi, 2015, A 99 nW 70.4 kHz resistive frequency locking on-chip oscillator with 27.4 ppm/°C temperature stability, Symp VLSI Circuits (VLSI Circuits) Dig Tech Papers, 238c
  23. 10.1109/TCSII.2006.889446 · DOI
  24. 10.1016/0250-6874(86)80037-3 · DOI
  25. griffith, 2014, A 190 nW 33 kHz RC oscillator with ±0.21% temperature stability and 4 ppm long-term stability, IEEE ISSCC Dig Tech Papers, 300
  26. 2014, ADS1234 Datasheet
  27. 10.1109/JSSC.2005.858476 · DOI

Metadata

Authors
Cai, Z., Rueda Guerrero, L. E., Louwerse, A. M. R., Suy, H., van Veldhoven, R., Makinwa, K. A. A., & Pertijs, M. A. P.
Affiliations
  • NXP (Netherlands) (NL)
  • Delft University of Technology (NL)
Venue
IEEE Sensors Journal
Published
2017-12-01
Volume
17
Issue
23
Pages
7917-7927
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W2765396864
Cited by
8
References
25
Citations by year
2026: 1 · 2024: 1 · 2022: 2 · 2021: 1 · 2020: 1 · 2018: 2
FWCI
0.37
Type
journal article
Language
en
Open access
Locations
  • IEEE Sensors Journal (publishedVersion)
  • Research Repository (Delft University of Technology) (submittedVersion, cc-by-nc-nd)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
Funders
  • NXP Semiconductors, The Netherlands
  • ams AG, The Netherlands
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
CMOS readout circuit, resistive sensors, thermal flow sensor, thermal conductivity sensor, bandgap voltage reference, polysilicon resistors, front-end integrated circuit

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review