The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Movement Decomposition and Machine Learning-Based Fall Detection System Using Wrist Wearable Device
Abstract
Falls in the elderly is a world health problem. Although many fall detection solutions were presented in literature, few of them are wrist-wearable devices, mainly due to typical processing and classification challenges to achieve accuracy greater than 95%. Considering the wrist as a more comfortable, discrete and acceptable place for an elderly wearable device, this paper presents the development and evaluation of a wrist-worn fall detection solution. Different sensors (accelerometer, gyroscope, and magnetometer), signals (acceleration, velocity, and displacement), and direction components (vertical and non-vertical) were combined and a comprehensive set of threshold-based and machine learning methods were applied in order to define the best approach for fall detection. Data was acquired for fall and non-fall movements from 22 volunteers. For threshold-based methods, a maximum accuracy of 91.1% was achieved with 95.8% and 86.5% of sensitivity and specificity, respectively, using Madgwick's decomposition. With the same movement decomposition and machine learning methods in the classification stage, an impressive accuracy of 99.0% was achieved, with 100% of sensitivity and 97.9% of specificity in our data set. Prolonged tests with a volunteer wearing the fall detector also demonstrate the advantages of machine learning methods in terms of practical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
Creating and benchmarking a new dataset for physical activity monitoring
Reiss, A., & Stricker, D. (2012) · Proceedings of the 5th International Conference on PErvasive Technologies Related to Assistive Environments · doi:10.1145/2413097.2413148 · Cited by 295 · cited 2×
“The general characteristics of the involved volunteers are: Unfortunately, public available datasets [26], [27] are not directly applicable in our approach, due to specificity of the sensors (parameters and configurations) and experimental protocol.”
Background
Cited by
Elderly Fall Detection Systems: A Literature Survey
Wang, X., Ellul, J., & Azzopardi, G. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.00071 · Cited by 380
Research of Fall Detection and Fall Prevention Technologies: A Systematic Review
Ren, L., & Peng, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2922708 · Cited by 266
Machine Learning and AI Technologies for Smart Wearables
Seng, K. P., Ang, L.-M., Peter, E., & Mmonyi, A. (2023) · Electronics · doi:10.3390/electronics12071509 · Cited by 90
Huang, M., & Garcia, A. (2023) · Applied Sciences · doi:10.3390/app132011379 · Cited by 9
Michaels, R., Barreira, T. V., Robinovitch, S. N., Sosnoff, J. J., & Moon, Y. (2025) · Scientific Reports · doi:10.1038/s41598-025-85934-y · Cited by 9
Metadata
- Authors
- de Quadros, T., Lazzaretti, A. E., & Schneider, F. K.
- Venue
- IEEE Sensors Journal
- Published
- 2018-06-15
- Volume
- 18
- Issue
- 12
- Pages
- 5082-5089
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2802084776
- Cited by
- 179
- References
- 2
- FWCI
- 8.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Movement Decomposition and Machine Learning-Based Fall Detection System Using Wrist Wearable Device. https://app.cochat.ai/papers/10.1109/jsen.2018.2829815
- The paper
- de Quadros, T., Lazzaretti, A. E., & Schneider, F. K. (2018). A Movement Decomposition and Machine Learning-Based Fall Detection System Using Wrist Wearable Device. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2018.2829815
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.