CoChat

Real-Time Intended Knee Joint Motion Prediction by Deep-Recurrent Neural Networks

Huang, Yongchuang, He, Zexia, Liu, Yuxuan, Yang, Ruiyuan, Zhang, Xiufeng, Cheng, Guang, Yi, Jingang, Ferreira, Joao Paulo, Liu, Tao · 2019 · IEEE Sensors Journal

The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.

Abstract

Human-assisting intelligent systems demand certain methods to precisely predict motorized limb joint angles. This paper presents the application of deep-recurrent neural networks (RNNs), which is a type of neural network for processing sequential data, for predicting the knee joint angle in real-time. This model is created based on a combination of electromyographic (EMG) signals, (with electrodes being placed on three leg muscles), and inertial measurements of the upper and lower legs. The data collected from different subjects when they performed different gaits were used to construct the model, which was evaluated in a real-time setting. The proposed RNN model based on fusion information contains a balance between computational complexity and prediction accuracy. Results on a microcontroller show that, within a predicted horizon of 50 ms, the model has a low prediction error of ±2.93 degrees.

Overview

Integrity signals

Registry

Crossref · 10.1109/jsen.2019.2933603

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Research works printed but not linked: 2

  1. ng, 2017, Why is deep learning taking off?
  2. 2018, Getting started with the Keras functional API

Cited by

See all 113

Metadata

Authors
Huang, Y., He, Z., Liu, Y., Yang, R., Zhang, X., Cheng, G., Yi, J., Ferreira, J. P., & Liu, T.
Affiliations
  • State Key Laboratory Fluid Power and Mechatronic Systems (CN)
  • Ministry of Civil Affairs (CN)
  • Beijing Union University (CN)
  • Rutgers, The State University of New Jersey (US)
Venue
IEEE Sensors Journal
Published
2019-12-01
Volume
19
Issue
23
Pages
11503-11509
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W2965100371
Cited by
105
References
29
Citations by year
2026: 6 · 2025: 21 · 2024: 19 · 2023: 20 · 2022: 16 · 2021: 17 · 2020: 5 · 2019: 1
FWCI
3.44
Type
journal article
Language
en
Open access
closed
Locations
IEEE Sensors Journal (publishedVersion)
Funders
  • National Natural Science Foundation of China (51775485, U1613203)
  • Beijing Municipal Commission of Education (KZ201811417048)
  • Northwestern Polytechnical University (2018QNA4004)
  • Fundação para a Ciência e a Tecnologia
  • COMPETE 2020 Program Automatic Adaptation of a Humanoid Robot Gait to Different Floor-Robot Friction Coefficients (PTDC/EEI-AUT/5141/2014)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Computer Science › Computer Graphics and Computer-Aided Design › Human Motion and Animation
Keywords
deep recurrent neural networks, electromyography, inertial measurement unit, gait, real-time prediction, sensor fusion, microcontroller implementation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-Time Intended Knee Joint Motion Prediction by Deep-Recurrent Neural Networks. https://app.cochat.ai/papers/10.1109/jsen.2019.2933603
The paper
Huang, Y., He, Z., Liu, Y., Yang, R., Zhang, X., Cheng, G., Yi, J., Ferreira, J. P., & Liu, T. (2019). Real-Time Intended Knee Joint Motion Prediction by Deep-Recurrent Neural Networks. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2019.2933603

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.