Balanced Resistive Matrix Array for High-Density Electrochemical Sensor Array
Abstract
In recent eras, many studies have been reported on sensitive and cost-effective electrochemical sensors based on various classes of nanocomposites fabricated by different methods for detecting multiple target analytes. Its application is boundless, from reactive monitoring of food additives and human health to environmental safety. One of the most efficient ways to read a set of electrochemical sensors for a portable system is to organize them in an array form. Sharing columns and rows, also called a “2-D networked array,” is generally adopted to compose the array form. This work presents a precise and compact electrochemical readout for a high-density 2-D networked chemiresistor array with a wide range on a printed circuit board (PCB) of$57.30\,\,{\times }\,\,37.10$mm, which is suitable as a portable system. The proposed electric readout for the electrochemical sensing system can measure the high-density 2-D networked chemiresistor array ranging from 100 K to 1 M with less than a 2% error rate.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 48 · Cited by 4
- Authors
- Park, H., Sun, Y., & Jung, S.
- Affiliations
- The University of Texas at Arlington (US)
- Venue
- IEEE Sensors Journal
- Published
- 2023-07-01
- Volume
- 23
- Issue
- 13
- Pages
- 14323-14329
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W4376481167
- Cited by
- 4
- References
- 48
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 1
- FWCI
- 0.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Keywords
- electrochemical sensor array, printed circuit boards, portable sensing system, nanocomposite sensors, multi-analyte detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review