The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A cmos chip for individual cell manipulation and detection
Abstract
Manipulation of populations of living cells on an individual basis is essential for the investigation of complex interactions among cells. We present a new approach to the integration on silicon of dielectrophoretic actuators and optical sensors that allow us to carry out this task. The device presented in this paper is an 8×8 mm2chip implemented in a two-poly three-metal 0.35-μm CMOS technology, featuring 102,400 actuation electrodes, arranged in an array of 320×320, 20 μm×20μm microsites each comprising addressing logic, an embedded memory for electrode programming, and an optical sensor. The chip enables software-controlled displacement of more than 10,000 individual living cells, allowing biologists to devise complex interaction protocols that are impossible to manage otherwise. The manipulation does not damage the viability of the cells, so that this approach could be a unique extension to the techniques already available to biologists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
A 3-D microelectrode system for handling and caging single cells and particles
Müller, T., Gradl, G., Howitz, S., Shirley, S., Schnelle, T., & Fuhr, G. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00006-8 · Cited by 242
Manz, A., Fettinger, J. C., Verpoorte, E., Lüdi, H., Widmer, H. M., & Harrison, D. J. (1991) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(91)85116-9 · Cited by 228
Cited by
Massively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Circulating tumor cell technologies
Ferreira, M. M., Ramani, V. C., & Jeffrey, S. S. (2016) · Molecular Oncology · doi:10.1016/j.molonc.2016.01.007 · Cited by 511
On-chip micromanipulation and assembly of colloidal particles by electric fields
Velev, O. D., & Bhatt, K. H. (2006) · Soft Matter · doi:10.1039/b605052b · Cited by 361
Metadata
- Authors
- Manaresi, N., Romani, A., Medoro, G., Altomare, L., Leonardi, A., Tartagni, M., & Guerrieri, R.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2003-12
- Volume
- 38
- Issue
- 12
- Pages
- 2297-2305
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2154010883
- Cited by
- 314
- References
- 3
- FWCI
- 14.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A cmos chip for individual cell manipulation and detection. https://app.cochat.ai/papers/10.1109/jssc.2003.819171
- The paper
- Manaresi, N., Romani, A., Medoro, G., Altomare, L., Leonardi, A., Tartagni, M., & Guerrieri, R. (2003). A cmos chip for individual cell manipulation and detection. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2003.819171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.