A 7 bit, 3.75 ps Resolution Two-Step Time-to-Digital Converter in 65 nm CMOS Using Pulse-Train Time Amplifier
The DOI matches its Crossref record.
Abstract
In this paper, a novel pulse-train time amplifier is proposed that achieves linear, accurate, and programmable gain for a wide input range. Using the proposed pulse-train time amplifier, a 7-bit two-step TDC is implemented. The proposed TDC employs repetitive pulses with gated delay-lines for a calibration-free and programmable time amplification and quantization. The prototype chip fabricated in 65 nm CMOS process achieves 3.75 ps of time resolution at 200 MS/s while consuming 3.6 mW and occupying 0.02 mm2area. Compared to previously reported TDCs, the proposed TDC achieves the fastest conversion rate and the best FoM without any calibration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A CMOS Integrator-Based Clock-Free Time-to-Digital Converter for Home-Monitoring LiDAR Sensors
He, Y., & Park, S. M. (2022) · Sensors · doi:10.3390/s22020554 · Cited by 5
Metadata
- Authors
- Kim, K., Kim, Y.-H., Yu, W., & Cho, S.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2013-04
- Volume
- 48
- Issue
- 4
- Pages
- 1009-1017
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W1993597884
- Cited by
- 167
- References
- 0
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 7 bit, 3.75 ps Resolution Two-Step Time-to-Digital Converter in 65 nm CMOS Using Pulse-Train Time Amplifier. https://app.cochat.ai/papers/10.1109/jssc.2013.2237996
- The paper
- Kim, K., Kim, Y.-H., Yu, W., & Cho, S. (2013). A 7 bit, 3.75 ps Resolution Two-Step Time-to-Digital Converter in 65 nm CMOS Using Pulse-Train Time Amplifier. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2013.2237996
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.