The DOI matches its Crossref record.
Data-Stream-Based Intrusion Detection System for Advanced Metering Infrastructure in Smart Grid: A Feasibility Study
Abstract
As advanced metering infrastructure (AMI) is responsible for collecting, measuring, and analyzing energy usage data, as well as transmitting this information from a smart meter to a data concentrator and then to a headend system in the utility side, the security of AMI is of great concern in the deployment of smart grid. In this paper, we analyze the possibility of using data stream mining for enhancing the security of AMI through an intrusion detection system (IDS), which is a second line of defense after the primary security methods of encryption, authentication, authorization, etc. We propose a realistic and reliable IDS architecture for the whole AMI system, which consists of individual IDSs for three different levels of AMI's components: smart meter, data concentrator, and AMI headend. We also explore the performances of various existing state-of-the-art data stream mining algorithms on a publicly available IDS data set, namely, the KDD Cup 1999 data set. Then, we conduct a feasibility analysis of using these existing data stream mining algorithms, which exhibit varying levels of accuracies, memory requirements, and running times, for the distinct IDSs at AMI's three different components. Our analysis identifies different candidate algorithms for the different AMI components' IDSs, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cyber-security in smart grid: survey and challenges
Mrabet, Z. E., Kaabouch, N., Ghazi, H. E., & Ghazi, H. E. (2018) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2018.01.015 · Cited by 482
Cyber‐physical attacks and defences in the smart grid: a survey
He, H., & Yan, J. (2016) · IET Cyber-Physical Systems: Theory & Applications · doi:10.1049/iet-cps.2016.0019 · Cited by 454
A Survey on Security Communication and Control for Smart Grids Under Malicious Cyber Attacks
Peng, C., Sun, H., Yang, M., & Wang, Y.-L. (2019) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2018.2884952 · Cited by 400
DeepCoin: A Novel Deep Learning and Blockchain-Based Energy Exchange Framework for Smart Grids
Ferrag, M. A., & Maglaras, L. (2020) · IEEE Transactions on Engineering Management · doi:10.1109/tem.2019.2922936 · Cited by 358
Machine learning for streaming data: state of the art, challenges, and opportunities
Gomes, H. M., Read, J., Bifet, A., Barddal, J. P., & Gama, J. (2019) · ACM SIGKDD Explorations Newsletter · doi:10.1145/3373464.3373470 · Cited by 267
Metadata
- Authors
- Faisal, M. A., Aung, Z., Williams, J. R., & Sanchez, A.
- Venue
- IEEE Systems Journal
- Published
- 2015-03
- Volume
- 9
- Issue
- 1
- Pages
- 31-44
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- 2373-7816
- OpenAlex
- W2103234848
- Cited by
- 177
- References
- 0
- FWCI
- 15.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Data-Stream-Based Intrusion Detection System for Advanced Metering Infrastructure in Smart Grid: A Feasibility Study. https://app.cochat.ai/papers/10.1109/jsyst.2013.2294120
- The paper
- Faisal, M. A., Aung, Z., Williams, J. R., & Sanchez, A. (2015). Data-Stream-Based Intrusion Detection System for Advanced Metering Infrastructure in Smart Grid: A Feasibility Study. IEEE Systems Journal. https://doi.org/10.1109/jsyst.2013.2294120
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.