Cited by 26Stroke Rehabilitation and RecoveryContext-Aware Activity Recognition SystemsArtificial Intelligence in Healthcare

Use of Accelerometry for Long Term Monitoring of Stroke Patients

Open access
Lucas, Alfredo, Hermiz, John, Labuzetta, Jamie, Arabadzhi, Yevgeniy, Karanjia, Navaz, Gilja, Vikash·2019·IEEE Journal of Translational Engineering in Health and Medicine

Abstract

Stroke patients are monitored hourly by physicians and nurses in an attempt to better understand their physical state. To quantify the patients' level of mobility, hourly movement (i.e. motor) assessment scores are performed, which can be taxing and time-consuming for nurses and physicians. In this paper, we attempt to find a correlation between patient motor scores and continuous accelerometer data recorded in subjects who are unilaterally impaired due to stroke. The accelerometers were placed on both upper and lower extremities of four severely unilaterally impaired patients and their movements were recorded continuously for 7 to 14 days. Features that incorporate movement smoothness, strength, and characteristic movement patterns were extracted from the accelerometers using time-frequency analysis. Support vector classifiers were trained with the extracted features to test the ability of the long term accelerometer recordings in predicting dependent and antigravity sides, and significantly above baseline performance was obtained in most instances ([Formula: see text]). Finally, a leave-one-subject-out approach was carried out to assess the generalizability of the proposed methodology, and above baseline performance was obtained in two out of the three tested subjects. The methodology presented in this paper provides a simple, yet effective approach to perform long term motor assessment in neurocritical care patients.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jtehm.2019.2897306

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 35 · Cited by 26

Research works printed but not linked: 34

  1. [1]Clark W. M., “ Recombinant tissue-type plasminogen activator (Alteplase) for ischemic stroke 3 to 5 hours after symptom onset: The ATLANTIS study: A randomized controlled trial,” JAMA, vol. 282, no. 21, pp. 2019– 2026, Dec. 1999. 10591384
  2. [2]Hermans G. and van den Berghe G., “ Clinical review: Intensive care unit acquired weakness,” Critical Care, vol. 19, no. 1, p. 274, Dec. 2015. 26242743 PMC4526175
  3. [3]Hislop H. J., Avers D., Brown M., and Daniels L., Daniels Worthingham’s Muscle Testing: Techniques of Manual Examination and Performance Testing. St. Louis, MO, USA: Elsevier, 2014.
  4. [4]Hand P. J., “ Interobserver agreement for the bedside clinical assessment of suspected stroke,” Stroke, vol. 37, no. 3, pp. 776– 780, Mar. 2006. 16484609
  5. [5]Salas R. E. and Gamaldo C. E., “ Adverse effects of sleep deprivation in the ICU,” Crit. Care Clinics, vol. 24, no. 3, pp. 461– 476, Jul. 2008. 18538195
  6. [6]Pandharipande P., “ Long-term cognitive impairment after critical illness,” New England J. Med., vol. 369, no. 14, pp. 1306– 1316, Oct. 2013. 24088092 PMC3922401
  7. [7]Verceles A. C. and Hager E. R., “ Use of accelerometry to monitor physical activity in critically ill subjects: A systematic review,” Respiratory Care, vol. 60, no. 9, pp. 1330– 1336, Sep. 2015. 25852167 PMC4582462
  8. [8]Raj R., Ussavarungsi K., and Nugent K., “ Accelerometer-based devices can be used to monitor sedation/agitation in the intensive care unit,” J. Crit. Care, vol. 29, no. 5, pp. 748– 752, 5 2014. 24973100
  9. [9]Mattlage A. E., Redlin S. A., Rippee M. A., Abraham M. G., Rymer M. M., and Billinger S. A., “ Use of accelerometers to examine sedentary time on an acute stroke unit,” J. Neurologic Phys. Therapy, vol. 39, no. 3, pp. 166– 171, Jul. 2015. PMC4470858 26035120
  10. [10]Kumar D., Gubbi J., Yan B., and Palaniswami M., “ Motor recovery monitoring in post acute stroke patients using wireless accelerometer and cross-correlation,” in Proc. 35th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. (EMBC), Jan. 2013, pp. 6693– 6703. 24111281
  11. [11]Gubbi J., Rao A. S., Fang K., Yan B., and Palaniswami M., “ Motor recovery monitoring using acceleration measurements in post acute stroke patients,” Biomed. Eng. Online, vol. 12, no. 1, p. 33, Dec. 2013. 23590690 PMC3680216
  12. [14]Grap M. J., “ Sedation in adults receiving mechanical ventilation: Physiological and comfort outcomes,” Amer. J. Crit. Care, vol. 21, no. 3, pp. e53– e64, 5 2012. 22549581 PMC3703630
  13. [15]Mannini A. and Sabatini A. M., “ Machine learning methods for classifying human physical activity from on-body accelerometers,” Sensors, vol. 10, no. 2, pp. 1154– 1175, Feb. 2010. 22205862 PMC3244008
  14. [16]Attal F., Mohammed S., Dedabrishvili M., Chamroukhi F., Oukhellou L., and Amirat Y., “ Physical human activity recognition using wearable sensors,” Sensors, vol. 15, no. 5, pp. 31314– 31338, Dec. 2015. 26690450 PMC4721778
  15. [17]Mannini A., Intille S. S., Rosenberger M., Sabatini A. M., and Haskell W., “ Activity recognition using a single accelerometer placed at the wrist or ankle,” Med. Sci. Sports Exerc., vol. 45, no. 11, pp. 2193– 2203, Nov. 2013. 23604069 PMC3795931
  16. [18]Alvarez R., Pulido E., and Sierra D. A., Climbing/Descending Stairs Detection Using Inertial Sensors and Implementing PCA and a SVM Classifier. New York, NY, USA: Springer, 2017.
  17. [19]Schmid M., “ SVM versus MAP on accelerometer data to distinguish among locomotor activities executed at different speeds,” Computational and mathematical methods in medicine, Epub, 2013. PMC3860084 24376469
  18. [20]Wu L. C., “ Detection of american football head impacts using biomechanical features and support vector machine classification,” Sci. Rep., vol. 8, p. 855, Dec. 2017. 29321637 PMC5762632
  19. [21]Anguita D., Ghio A., Oneto L., Parra X., and Reyes-Ortiz J. L., “ Human activity recognition on smartphones using a multiclass hardware-friendly support vector machine,” in Proc. Int. Workshop Ambient Assisted Living. New York, NY, USA, Springer, 2012, pp. 216– 223.
  20. [22]Davoudi A. (2018). “ The intelligent ICU pilot study: Using artificial intelligence technology for autonomous patient monitoring.” [Online]. Available: https://arxiv.org/abs/1804.10201 · arXiv
  21. [23]Casale P., Pujol O., and Radeva P., “ Classifying agitation in sedated ICU patients,” in MICCAT Workshop Proc., vol. 2, Nov. 2010.
  22. [24]Lee S., “ Constructing a Bio-Signal Repository from an Intensive Care Unit for Effective Big-data Analysis: Poster Abstract,” in Proc. 14th ACM Conf. Embedded Netw. Sensor Syst., Nov. 2016, pp. 372– 373.
  23. [25]Denehy L., “ A physical function test for use in the intensive care unit: Validity, responsiveness, and predictive utility of the physical function ICU test (Scored),” Phys. Therapy, vol. 93, pp. 1636– 1645, Dec. 2013. 23886842
  24. [26]Fuller J., Granton J., and McConachie I., Handbook ICU Therapy. Cambridge, U.K.: Cambridge Univ. Press, Dec. 2014.
  25. [27]Zhang S., Rowlands A. V., Murray P., and Hurst T. L., “ Physical activity classification using the GENEA wrist-worn accelerometer,” Med. Sci. Sports Exerc., vol. 44, pp. 742– 748, Apr. 2012. 21988935
  26. [28]Bayle N., “ Movement smoothness differentiates voluntary from parkinsonian bradykinesia,” J. Addiction Res. Therapy, vol. 7, pp. 1– 8, Jan. 2016.
  27. [29]Beck Y., Herman T., Brozgol M., Giladi N., Mirelman A., and Hausdorff J. M., “ SPARC: A new approach to quantifying gait smoothness in patients with Parkinson s disease,” J. NeuroEng. Rehabil., vol. 15, no. 1, p. 49, Jun. 2018. 29914518 PMC6006701
  28. [30]Cozens J. A. and Bhakta B. B., “ Measuring movement irregularity in the upper motor neurone syndrome using normalised average rectified jerk,” J. Electromyography Kinesiology, vol. 13, no. 1, pp. 73– 81, Feb. 2003. 12488089
  29. [31]Colas F. and Brazdil P., “ Comparison of SVM and Some Older Classification Algorithms in Text Classification Tasks,” in Proc. IFIP Int. Conf. Artif. Intell. Theory Pract., vol. 217, 2006, pp. 169– 178.
  30. [32]Pedregosa F., “ Scikit-learn: Machine Learning in Python,” Mach. Learn., vol. 12, pp. 2825– 2830, Oct. 2011.
  31. [33]Cortes C. and Vapnik V., “ Support-vector Networks,” Mach. Learn., vol. 20, pp. 273– 297, Sep. 1995.
  32. [35]Ibáñez V., Silva J., and Cauli O., “ A survey on sleep assessment methods,” PeerJ, vol. 6, p. e4849, 5 2018. 29844990 PMC5971842
  33. [36]van der Kooi A. W., “ Sleep monitoring by actigraphy in short-stay ICU patients,” Crit. Care Nursing Quart., vol. 36, pp. 169– 173, Jun. 2013. 23470702
  34. [38]Chen K., “ Patient-specific pose estimation in a clinical environmen,” in Proc. Socal Mach. Learn. Symp., Oct. 2017, pp. 1– 9.

Authors
Lucas, A., Hermiz, J., Labuzetta, J., Arabadzhi, Y., Karanjia, N., & Gilja, V.
Affiliations
University of California San Diego (US)
Corresponding author
Gilja, Vikash
Venue
IEEE Journal of Translational Engineering in Health and Medicine
Published
2019
Volume
7
Pages
1-10
ISSN
2168-2372 (ISSN-L)
OpenAlex
W2913602685
Cited by
26
References
35
Citations by year
2026: 1 · 2025: 1 · 2024: 4 · 2023: 7 · 2022: 6 · 2021: 6 · 2020: 1
FWCI
2.27
Type
journal article
Language
en
Open access
Locations
  • IEEE Journal of Translational Engineering in Health and Medicine (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • eScholarship (California Digital Library) (submittedVersion)
Funders
  • UCSD ECE Department Startup
  • NSF I-Corps
  • Dennis Washington Leadership Scholarship
Topics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
Keywords
stroke, accelerometry, long-term patient monitoring, motor function assessment, time-frequency analysis, support vector machine classification, motion features, neurocritical care, wearable sensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review