The DOI matches its Crossref record.
Tendon-Based Stiffening for a Pneumatically Actuated Soft Manipulator
Open accessAbstract
There is an emerging trend toward soft robotics due to its extended manipulation capabilities compared to traditionally rigid robot links, showing promise for an extended applicability to new areas. However, as a result of the inherent property of soft robotics being less rigid, the ability to control/obtain higher overall stiffness when required is yet to be further explored. In this letter, an innovative design is introduced which allows varying the stiffness of a continuum silicon-based manipulator and proves to have potential for applications in Minimally Invasive Surgery. Inspired by muscular structures occurring in animals such as the octopus, we propose a hybrid and inherently antagonistic actuation scheme. In particular, the octopus makes use of this principle activating two sets of muscles-longitudinal and transverse muscles-thus, being capable of controlling the stiffness of parts of its arm in an antagonistic fashion. Our designed manipulator is pneumatically actuated employing chambers embedded within the robot's silicone structure. Tendons incorporated in the structure complement the pneumatic actuation placed inside the manipulator's wall to allow variation of overall stiffness. Experiments are carried out by applying an external force in different configurations while changing the stiffness by means of the two actuation mechanisms. Our test results show that dual, antagonistic actuation increases the load bearing capabilities for soft continuum manipulators and thus their range of applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shintake, J., Cacucciolo, V., Floreano, D., & Shea, H. (2018) · Advanced Materials · doi:10.1002/adma.201707035 · Cited by 1,938
Soft Robotics in Minimally Invasive Surgery
Runciman, M., Darzi, A., & Mylonas, G. P. (2019) · Soft Robotics · doi:10.1089/soro.2018.0136 · Cited by 540
Soft Robotics: A Review of Recent Developments of Pneumatic Soft Actuators
Walker, J., Zidek, T., Harbel, C., Yoon, S., Strickland, F. S., Kumar, S., & Shin, M. (2020) · Actuators · doi:10.3390/act9010003 · Cited by 385
Discrete Cosserat Approach for Multisection Soft Manipulator Dynamics
Renda, F., Boyer, F., Dias, J., & Seneviratne, L. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2868815 · Cited by 335
Metadata
- Authors
- Shiva, A., Stilli, A., Noh, Y., Faragasso, A., Falco, I. D., Gerboni, G., Cianchetti, M., Menciassi, A., Althoefer, K., & Wurdemann, H. A.
- Venue
- IEEE Robotics and Automation Letters
- Published
- 2016-07
- Volume
- 1
- Issue
- 2
- Pages
- 632-637
- ISSN
- 2377-3766 (ISSN-L)
- 2377-3774
- OpenAlex
- W2293554515
- Cited by
- 216
- References
- 0
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tendon-Based Stiffening for a Pneumatically Actuated Soft Manipulator. https://app.cochat.ai/papers/10.1109/lra.2016.2523120
- The paper
- Shiva, A., Stilli, A., Noh, Y., Faragasso, A., Falco, I. D., Gerboni, G., Cianchetti, M., Menciassi, A., Althoefer, K., & Wurdemann, H. A. (2016). Tendon-Based Stiffening for a Pneumatically Actuated Soft Manipulator. IEEE Robotics and Automation Letters. https://doi.org/10.1109/lra.2016.2523120
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.