M-Health: The Development of Cuff-less and Wearable Blood Pressure Meters for Use in Body Sensor Networks
The DOI matches its Crossref record.
Abstract
To meet the needs of the increasingly aging population, development of wearable medical devices and body sensor networks technologies for applications in telemedicine and mobile health are imperative. In this direction, we have developed a cuff-less and noninvasive pulse transit time (PTT)-based approach to overcome the shortcomings of conventional invasive or cuff-based blood pressure (BP) measurement techniques for long-term and continuous measurement of BP and its variability. The technique is useful for designing wearable BP meters, which, if connected with various types of wearable devices by a body sensor network, could form a front-end infrastructure for long-term personal health monitoring. In this paper, we evaluated the PTT-based approach with data collected from two groups of 85 subjects. The results suggested that the PTT-based approach is a promising technique for the noninvasive and cuff-less measurement of BP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
Self-citationSmart wearable body sensors for patient self-assessment and monitoring
Appelboom, G., Camacho, E., Abraham, M. E., Bruce, S. S., Dumont, E. L., Zacharia, B. E., D’Amico, R., Slomian, J., Reginster, J. Y., Bruyère, O., et al. (2014) · Archives of Public Health · doi:10.1186/2049-3258-72-28 · Cited by 448
Smart Vest: Wearable multi-parameter remote physiological monitoring system
Pandian, P. S., Mohanavelu, K., Safeer, K. P., Kotresh, T. M., Shakunthala, D. T., Gopal, P., & Padaki, V. C. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.014 · Cited by 423
Detecting Vital Signs with Wearable Wireless Sensors
Yilmaz, T., Foster, R., & Hao, Y. (2010) · Sensors · doi:10.3390/s101210837 · Cited by 344
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310
“To use the system measuring BP regularly or continuously over extensive periods of time, the electrodes and photo detector can be incorporated into a watch [46] or a module that is wirelessly”
MethodSelf-citation
Metadata
- Authors
- Y. Poon, C., Wong, Y., & Zhang, Y.-T.
- Venue
- 2006 IEEE/NLM Life Science Systems and Applications Workshop
- Publisher
- IEEE
- Published
- 2006-07
- Pages
- 1-2
- OpenAlex
- W2111469736
- Cited by
- 55
- References
- 0
- FWCI
- 2.02
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: M-Health: The Development of Cuff-less and Wearable Blood Pressure Meters for Use in Body Sensor Networks. https://app.cochat.ai/papers/10.1109/lssa.2006.250377
- The paper
- Y. Poon, C., Wong, Y., & Zhang, Y.-T. (2006). M-Health: The Development of Cuff-less and Wearable Blood Pressure Meters for Use in Body Sensor Networks. 2006 IEEE/NLM Life Science Systems and Applications Workshop. https://doi.org/10.1109/lssa.2006.250377
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.