Harmonic Mitigation of Variable Speed Drive with Shunt Active Filter Connected via LCL Coupler
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Nowadays, the applications of nonlinear loads are extended to various types including variable speed drives, arc furnaces, computers and other electronic loads. These nonlinear loads generate harmonics, which cause excessive heating of conductors and pulsating torque of motors. This paper presents a shunt active filter used to mitigate the harmonic distortion produced by Variable Speed Drive (VSD) systems. A VSD load is connected at a certain bus in a simulated 14-bus Cigre benchmark distribution network. A shunt active filter is used to mitigate the VSD harmonics. The shunt active filter is controlled by a hysteresis controller and is coupled to the network through an LCL link. Harmonic analyses are performed using the fast Fourier transform and according to the IEEE Standard 519-2014. Three cases are considered: (i) no active filter; (ii) installing an active filter coupled to the network through an L link; and (iii) installing an active filter coupled through an LCL link. Simulation studies are performed by using the MATLAB/Simulink software. The results have shown that the shunt active filter with the LCL coupler reduces the harmonic distortion compared to the coupling through the L only.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402
(2008) · Wiley eBooks · doi:10.1002/9780470754245 · Cited by 566
Design and Performance Analysis of Three-Phase Solar PV Integrated UPQC
Devassy, S., & Singh, B. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2754983 · Cited by 220
Progress in Electromagnetics Research Symposium
(1997) · Annales Des Télécommunications · doi:10.1007/bf02998452 · Cited by 175
Comparison of L, LC & LCL filter for grid connected converter
Yagnik, U. P., & Solanki, M. D. (2017) · International Conference on Trends in Electronics and Informatics (ICOEI) · doi:10.1109/icoei.2017.8300968 · Cited by 57
Implementation of Solar Photovoltaic System With Universal Active Filtering Capability
Devassy, S., & Singh, B. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2906297 · Cited by 54
Jayasankar, V. N., & Vinatha, U. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.3025520 · Cited by 49
Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
Chelli, Z., Toufouti, R., Omeiri, A., & Saad, S. (2015) · Journal of Electrical and Computer Engineering · doi:10.1155/2015/391040 · Cited by 41
Power Quality Enhancement in PV and Battery Storage Based Microgrid Using Hybrid Active Filter
Das, S. R., Ray, P. K., Mohanty, A., & Panda, G. (2021) · International Conference on Energy, Power and Environment (ICEPE) · doi:10.1109/icepe50861.2021.9404453 · Cited by 23
Fayek, H. H., & Abdalla, O. H. (2022) · Smart Cities · doi:10.3390/smartcities5010003 · Cited by 20
Self-citationHarmonic Analysis of an Arc Furnace Load Based on the IEEE 519-2014 Standard
Abdalla, O. H., Elmasry, S. E., El-Korfolly, M. I., & Htita, I. (2022) · International Middle East Power Systems Conference (MEPCON) · doi:10.1109/mepcon55441.2022.10021725 · Cited by 18
Self-citationPower Quality Enhancement Using Active Shunt Harmonic Filter Based on PV
Gupta, S., Gill, A., & Singh, M. (2023) · International Conference on Intelligent and Innovative Technologies in Computing, Electrical and Electronics (IITCEE) · doi:10.1109/iitcee57236.2023.10090903 · Cited by 17
Maximization of Renewable Power Generation for Optimal Operation of the Egyptian Grid
Fayek, H. H., & Abdalla, O. H. (2020) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie45063.2020.9152450 · Cited by 16
Self-citationANN Based Fundamental Current Extraction Scheme for Single Phase Shunt Active Filtering
Sant, A. V., & Gohil, M. H. (2019) · International Conference on Electrical, Computer and Communication Technologies (ICECCT) · doi:10.1109/icecct.2019.8869032 · Cited by 10
Ouchen, S., Steinhart, H., Blaabjerg, F., et al. (2019) · Proceedings of the Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2019.8926724 · Cited by 10
Current control schemes for three-phase fourwire shunt active power filters: a comparative study
Suárez, J. F. P., Amarís, H., & Robles, G. (2010) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 9
Enhancement of Power Quality with a Wind-Integrated Shunt Active Power Filter
Teja, T. S. V. S. P., Prince, S. K., Maheswar., R., et al. (2022) · International Conference on Energy, Power and Environment (ICEPE) · doi:10.1109/icepe55035.2022.9798292 · Cited by 9
Design of Shunt Active Power Filter Using Reference Frame Theory For Power Quality Improvement
Kore, V. D., Fernandes, M., & Ahire, N. R. (2018) · International Conference on Advances in Electrical, Electronics, Information, Communication and Bio-Informatics · doi:10.1109/aeeicb.2018.8480977 · Cited by 8
El-Saady, G., Ebrahim, E. A., Abdul‐Ghaffar, H. I., et al. (2018) · IEEE Congress on Evolutionary Computation (CEC) · doi:10.1109/cec.2018.8477653 · Cited by 8
Soukhtekouhi, M. R., Hamzeh, M., & Iman‐Eini, H. (2020) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc49159.2020.9088378 · Cited by 8
GCDSC-PLL and PAC Based Control of Three-Phase Four-Wire UPQC for Power Quality Improvement
Sharma, A., & Gupta, N. (2019) · International Conference on Electrical Energy Systems (ICEES) · doi:10.1109/icees.2019.8719312 · Cited by 6
Azzam-Jai, A., & Ouassaid, M. (2019) · International Conference on Intelligent Computing in Data Sciences (ICDS) · doi:10.1109/icds47004.2019.8942282 · Cited by 6
Harmonic Analysis Using Wavelet Transform for Active Power Filter Applications
MuniaSelvan, L., & Rathika, P. (2019) · IEEE International Conference on Intelligent Techniques in Control, Optimization and Signal Processing (INCOS) · doi:10.1109/incos45849.2019.8951337 · Cited by 6
Mukherjee, S., Mazumder, S., & Adhikary, S. (2020) · IEEE VLSI Device Circuit and System (VLSI DCS) · doi:10.1109/vlsidcs47293.2020.9179882 · Cited by 6
Performance Analysis of an Adaptive Hysteresis Band Current Controller based Active Power Filter
Misra, B., Tripathy, P., Mohanty, R., et al. (2022) · International Conference on Advances in Electrical, Computing, Communication and Sustainable Technologies (ICAECT) · doi:10.1109/icaect54875.2022.9807992 · Cited by 6
Pawar, M. R., & Bavdhane, V. D. (2022) · 2022 IEEE International Conference on Data Science and Information System (ICDSIS) · doi:10.1109/icdsis55133.2022.9915995 · Cited by 6
Passive, active and hybrid filters as a part of the energy efficient electrical drives curriculum
Vukojičić, S., Pavlovic, S., & Ristić, L. (2019) · International Symposium on Power Electronics (Ee) · doi:10.1109/pee.2019.8923030 · Cited by 5
Chavali, R. V., Dey, A., & Das, B. (2020) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre45664.2020.9070694 · Cited by 5
Mitigation of Harmonics in Voltage and Current Using UPQC
Srivastav, A., Chauhan, A., & Tripathi, A. (2020) · International Conference on Power Electronics & IoT Applications in Renewable Energy and its Control (PARC) · doi:10.1109/parc49193.2020.236654 · Cited by 5
Espinosa, T. B. P., & Magwili, G. V. (2022) · International Conference on Computer and Automation Engineering · doi:10.1109/iccae55086.2022.9762417 · Cited by 5
Satish, G., Rameshkumar, K., Dhanasakkaravarthi, B., Jeyalakshmi, K., Chaudhary, S., & Singh, N. (2023) · International Conference on Integrated Circuits and Communication Systems (ICICACS) · doi:10.1109/icicacs57338.2023.10099957 · Cited by 5
Synchronous Reference Frame Theory Based Shunt Active Filter For Harmonic and Unbalance Compensation
Abirami, T., Surasmi, N. L., Vinod, B. R., et al. (2023) · International Conference on Control, Communication and Computing (ICCC) · doi:10.1109/iccc57789.2023.10165198 · Cited by 5
Sharifian, M. B. B., Rahnavard, R., & Ebrahimi, Y. (2009) · International Journal of Computer and Electrical Engineering · doi:10.7763/ijcee.2009.v1.36 · Cited by 4
Andang, A., Hartarti, R. S., Manuaba, I. B. G., et al. (2019) · doi:10.1109/icsecc.2019.8907158 · Cited by 3
Harmonic Mitigation Using Shunt Active Power Filter Under Various Loading Condition
Bhowmik, A. R., & Mukherjee, S. (2019) · International Conference on Electrical, Electronics, Communication, Computer Technologies and Optimization Techniques (ICEECCOT) · doi:10.1109/iceeccot46775.2019.9114631 · Cited by 3
Performance Evaluation of Shunt Active Power Filter for Aircraft System
Kumar, U., & Kumar, S. (2020) · doi:10.1109/ice348803.2020.9122873 · Cited by 3
Suru, C. V., Popescu, M., & Dobriceanu, M. (2019) · doi:10.1109/iseee48094.2019.9136113 · Cited by 3
Ramesh, P., Palanisamy, K., Paramasivam, S., et al. (2019) · Innovations in Power and Advanced Computing Technologies (i-PACT) · doi:10.1109/i-pact44901.2019.8960226 · Cited by 2
Voncilă, I., Roşu, E. M., Gurguiatu, G., et al. (2019) · doi:10.1109/iseee48094.2019.9136115 · Cited by 2
Fuzzy logic compensator of harmonic currents on shunt filter for photovoltaic generator
Marwa, M. B., & Mansouri, M. M. N. (2019) · International Renewable Energy Congress · doi:10.1109/irec.2019.8754521 · Cited by 1
Design and Simulation of Shunt Active Filter using Fuzzy Logic
Harwani, D., Arya, S., & Shah, K. P. (2019) · Innovations in Power and Advanced Computing Technologies (i-PACT) · doi:10.1109/i-pact44901.2019.8959519 · Cited by 1
Fuel Cell Based Sapf System with Dual Mode Operation
Patnaik, N., Panda, A. K., & Pandey, R. (2020) · International Conference on Devices, Circuits and Systems (ICDCS) · doi:10.1109/icdcs48716.2020.243564 · Cited by 1
Chavali, R. V., Dey, A., Das, B., et al. (2022) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre52268.2022.9715822 · Cited by 1
Research works printed but not linked: 4
- Abdalla, 2019, Technical Requirements for Connecting Solar Power Plants to Electricity Networks” Book Chapter in “Innovation in Energy Systems - New Technologies for Changing Paradigms, IntechOpen, 1
- Abdalla, 2023, Technical Requirements of Connecting Wind Farms to the Egyptian Grid Based on the Wind Farm Grid Connection Code, Journal of the Egyptian Society of Engineers, 62, 16
- 2018, Microgrid Stability Definitions, Analysis, and Modeling
- Lettl, Comparison of different filter types for grid connected inverter, 1426
Cited by
Shunt Active Power Filters in Three-Phase, Three-Wire Systems: A Topical Review
Popescu, M., Bitoleanu, A., Suru, C. V., et al. (2024) · Energies · doi:10.3390/en17122867 · Cited by 46
“The algorithms for the reference current generation in the frequency domain are mainly based on Fourier analysis of the distorted load currents, which involves either fast Fourier transform (FFT) [20,21,106,212–214] or, more frequently, discrete Fourier transform (DFT) [20,100,145,211,215–217].”
BackgroundMethodTopology design of variable speed drive systems for enhancing power quality in industrial grids
Nadweh, S., Mohammed, N., Alshammari, O., et al. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.111114 · Cited by 9
Özer, A. S., Sevilmiş, F., Karaca, H., & Ahmed, H. (2026) · Protection and Control of Modern Power Systems · doi:10.23919/pcmp.2025.000070 · Cited by 16
Li, S., Mao, Y., & Zheng, Z. (2025) · Journal of Power Electronics · doi:10.1007/s43236-024-00985-0 · Cited by 1
“According to IEEE standard 519-2014, a total demand distortion (TDD) analysis is conducted on the grid-connected current [18, 19].”
Study of the Flicker Phenomenon Induced in the Electric Arc Furnace of the Steel Factory in Tunisia
Tlili, F., Slimene, M. B., Khlifi, M. A., et al. (2024) · IEEE Access · doi:10.1109/access.2024.3502428 · Cited by 1
Metadata
- Authors
- El Korfolly, M. I., Htita, I., Elmasry, S., & Abdalla, O. H.
- Affiliations
- Helwan University,Faculty of Engineering at Helwan,Dept. of Electrical Power and Machines Engineering,Cairo,Egypt
- Helwan University (EG)
- ORCID
- Abdalla, Omar H.
- Venue
- 2023 24th International Middle East Power System Conference (MEPCON)
- Publisher
- IEEE
- Published
- 2023-12-19
- Pages
- 1-7
- OpenAlex
- W4392904912
- Semantic Scholar
- 6c1c2fa682c8f1c241c770bedbd57cefc5457858
- Cited by
- 5
- References
- 44
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3
- FWCI
- 2.45
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Middle East Power Systems Conference (MEPCON) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
- Keywords
- harmonic compensation, shunt active power filter, variable frequency drive, nonlinear loads, hysteresis current control, harmonic distortion, IEEE 519-2014, power quality
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.