Building Energy Management Systems: The Age of Intelligent and Adaptive Buildings
Abstract
Building automation systems (BAS), or building control systems (BCS), typically consist of building energy management systems (BEMSs), physical security and access control, fire/life safety, and other systems (elevators, public announcements, and closed-circuit television). BEMSs control heating, ventilation, and air conditioning (HVAC) and lighting systems in buildings; more specifically, they control HVAC's primary components such as air handling units (AHUs), chillers, and heating elements. BEMSs are essential components of modern buildings, tasked with seemingly contradicting requirements?minimizing energy consumption while maintaining occupants? comfort [1]. In the United States, about 40% of total energy consumption and 70% of electricity consumption are spent on buildings every year. These numbers are comparable to global statistics that about 30% of total energy consumption and 60% of electricity consumption are spent on buildings. Buildings are an integral part of global cyber-physical systems (smart cities) and evolve and interact with their surroundings. As buildings undergo years of exploitation, their thermal characteristics deteriorate, indoor spaces (especially in commercial buildings) get rearranged, and usage patterns change. In time, their inner (and outer) microclimates adjust to changes in surrounding buildings, overshadowing patterns, and city climates, not to mention building retrofitting. Thus, even in cases of ideally designed BEMS/HVAC systems, because of ever-changing and uncertain indoor and outdoor environments, their performance frequently falls short of expectations. Unfortunately, the complexity of BEMSs, large amounts of constantly changing data, and evolving interrelations among sensor feeds make identifying these suboptimal behaviors difficult. Therefore, traditional data-mining algorithms and data-analysis tools are often inadequate.This article provides an overview of issues related to modern BEMSs with a multitude of (often conflicting) requirements. Because of massive and often incomplete data sets, control, sensing, and the evolving nature of these complex systems, computational intelligence (CI) techniques present a natural solution to optimal energy efficiency, energy security, and occupant comfort in buildings. The article further presents an overall architecture where CI can be used in BEMSs and concludes with a case study of the practical applications of using CI techniques in the BEMS domain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
A new optimizer using particle swarm theory
Eberhart, R., & Kennedy, J. (2002) · MHS'95. Proceedings of the Sixth International Symposium on Micro Machine and Human Science · doi:10.1109/mhs.1995.494215 · Cited by 16,067 · cited 1×
“Each of these factors was minimized using the PSO technique [85].”
MethodA review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649 · cited 1×
“Because of the high energy consumption, buildings are also one of the major contributors to greenhouse gas production [10], [11]–[12], but also offer the greatest cost potential for achieving significant greenhouse gas emission reductions, with numbers projected to increase [11], [13].”
BackgroundTowards a Conceptual Framework for Resilience Engineering
Madni, A. M., & Jackson, S. (2009) · IEEE Systems Journal · doi:10.1109/jsyst.2009.2017397 · Cited by 649 · cited 2×
“While some go back to Madni and Jackson’s [26] systems resilience definition addressing “.”
BackgroundWang, L., Wang, Z., & Yang, R. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2178044 · Cited by 235
Cited by
Tushar, W., Yuen, C., Saha, T. K., Morstyn, T., Chapman, A. C., Alam, M. J. E., Hanif, S., & Poor, H. V. (2021) · Applied Energy · doi:10.1016/j.apenergy.2020.116131 · Cited by 523
O’Dwyer, E., Pan, I., Acha, S., & Shah, N. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.024 · Cited by 410
Deep neural networks for energy load forecasting
Amarasinghe, K., Marino, D. L., & Manic, M. (2017) · 2017 IEEE 26th International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2017.8001465 · Cited by 336
Self-citationNILM Techniques for Intelligent Home Energy Management and Ambient Assisted Living: A Review
Ruano, A., Hernandez, A., Ureña, J., Ruano, M., & Garcia, J. (2019) · Energies · doi:10.3390/en12112203 · Cited by 271
Real-Time Emulation of Residential Buildings by Hardware Solution of Multi-Layer Model
Guzman, C., Agbossou, K., & Cardenas, A. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2848727 · Cited by 13
“number of defined layers of the building elements, and these represent the order of the model [4], [8], [20].”
Background
Metadata
- Authors
- Manic, M., Wijayasekara, D., Amarasinghe, K., & Rodriguez-Andina, J. J.
- Venue
- IEEE Industrial Electronics Magazine
- Published
- 2016-03
- Volume
- 10
- Issue
- 1
- Pages
- 25-39
- ISSN
- 1932-4529 (ISSN-L)
- OpenAlex
- W2307544986
- Cited by
- 249
- References
- 5
- FWCI
- 32.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.