The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A Power Electronic-Based Distribution Transformer
Abstract
The distribution transformer has been in use by utilities throughout the twentieth century. Until now, it has consisted of a configuration of iron or steel cores and copper/aluminum coils, with mineral oil serving as both coolant and dielectric medium. Inherent in this type of construction are regulation, significant weight, losses, environmental concerns, and power quality issues. A new kind of distribution transformer is proposed for the twenty-first century, one that can be made self-regulating, oil-free, and able to correct power quality problems. A power electronic transformer has been analyzed, simulated, prototyped, and tested. Results of this effort, as well as the novel features of this new type of transformer, are discussed herein.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Power Electronics
Kassakian, J. G., Perreault, D. J., Verghese, G. C., & Schlecht, M. F. (2023) · Cambridge University Press eBooks · doi:10.1017/9781009023894 · Cited by 1,394
Input filter considerations in design and application of switching regulators.
Middlebrook, R. D. (1976) · Medical Entomology and Zoology · Cited by 1,180
Analysis and design of electronic transformers for electric power distribution system
Kang, M., Enjeti, P. N., & Pitel, I. J. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.803407 · Cited by 365
A digitally controlled AC to DC power conditioner that draws sinusoidal input current
Henze, C. P., & Mohan, N. (1986) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1986.7415604 · Cited by 98
Solid State Transformer Concept Development.
Brooks, J. L. (1980) · Defense Technical Information Center (DTIC) · Cited by 75
Cited by
The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Smart Transmission Grid: Vision and Framework
Li, F., Qiao, W., Sun, H., Wan, H., Wang, J., Xia, Y., Xu, Z., & Zhang, P. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2053726 · Cited by 961
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642
Applicability of solid-state transformers in today's and future distribution grids
Huber, J. E., & Kolar, J. W. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2738610 · Cited by 506
Metadata
- Authors
- Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L.
- Venue
- IEEE Power Engineering Review
- Published
- 2002-03
- Volume
- 22
- Issue
- 3
- Pages
- 61-61
- ISSN
- 0272-1724 (ISSN-L)
- 1558-1705
- OpenAlex
- W2126455698
- Cited by
- 264
- References
- 5
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.