Electric shock hazard
The DOI matches its Crossref record.
Abstract
A long-standing expert on electric-shock hazards summarizes the studies that determined the effective body impedance under varying conditions. He describes perception currents, reaction currents, let-go currents, and fibrillating currents. Turning to means for reducing low-voltage (120-240-volt) hazards, double insulation, shock limitation, isolation transformers, and the use of either high frequency or direct current are discussed for various environments. Macroshock is always a hazard in the home, in industry, and in the hospital. But the extreme vulnerability to microshock of patients with cardiac catheters, for example, requires special precautions in intensive-care and coronary-care units. Equipment such as the ground-fault interrupter (GFI) and a special isolation transformer are cited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peripheral nerve stimulation by induced electric currents: Exposure to time-varying magnetic fields
Reilly, J. P. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446217 · Cited by 293
Design Guideline for Developing Safe Systems that Apply Electricity to the Human Body
Kono, M., Takahashi, T., Nakamura, H., Miyaki, T., & Rekimoto, J. (2018) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3184743 · Cited by 63
“However, Dalziel [32] reported that the threshold increases in high-frequency conditions.”
Background
Metadata
- Authors
- Dalziel, C. F.
- Venue
- IEEE Spectrum
- Published
- 1972-02
- Volume
- 9
- Issue
- 2
- Pages
- 41-50
- ISSN
- 0018-9235 (ISSN-L)
- OpenAlex
- W2029315598
- Cited by
- 209
- References
- 0
- FWCI
- 38.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.