The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT
Abstract
The HRRT PET system has the potential to produce human brain images with resolution better than 3 mm. To achieve the best possible accuracy and precision, we have designed MOLAR, a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction on a computer cluster with the following features: direct use of list mode data with dynamic motion information (Polaris); exact reprojection of each line-of- response (LOR); system matrix computed from voxel-to-LOR distances (radial and axial); spatially varying resolution model implemented for each event by selection from precomputed line spread functions based on factors including detector obliqueness, crystal layer, and block detector position; distribution of events to processors and to subsets based on order of arrival; removal of voxels and events outside a reduced field-of-view defined by the attenuation map; no pre-corrections to Poisson data, i.e., all physical effects are defined in the model; randoms estimation from singles; model-based scatter simulation incorporated into the iterations; and component-based normalization. Preliminary computation estimates suggest that reconstruction of a single frame in one hour is achievable. Careful evaluation of this system will define which factors play an important role in producing high resolution, low-noise images with quantitative accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Self-citationNew, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
A system for the 3D reconstruction of retracted-septa PET data using the EM algorithm
Johnson, C. A., Yan, Y., Carson, R. E., Martino, R. L., & Daube-Witherspoon, M. E. (1995) · IEEE Transactions on Nuclear Science · doi:10.1109/23.467875 · Cited by 93
Self-citationModel-based normalization for iterative 3D PET image reconstruction
Bai, B., Li, Q., Holdsworth, C. H., Asma, E., Tai, Y., Chatziioannou, A. F., & Leahy, R. M. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/15/316 · Cited by 80
Parameter Estimation for Dynamic Studies in Emission-Tomography Systems Having List-Mode Data
Snyder, D. L. (1984) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1984.4333400 · Cited by 75
The design and implementation of COSEN, an iterative algorithm for fully 3-D listmode data
Levkovilz, R., Falikman, D., Zibulevsky, M., Ben‐Tal, A., & Nemirovski, A. S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932747 · Cited by 66
Cited by
Imaging synaptic density in the living human brain
Finnema, S. J., Nabulsi, N. B., Eid, T., Detyniecki, K., Lin, S.-F., Chen, M.-K., Dhaher, R., Matuskey, D., Baum, E., Holden, D., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6667 · Cited by 575
Self-citationImaging robust microglial activation after lipopolysaccharide administration in humans with PET
Sandiego, C. M., Gallezot, J.-D., Pittman, B., Nabulsi, N., Lim, K., Lin, S.-F., Matuskey, D., Lee, J.-Y., O’Connor, K. C., Huang, Y., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1511003112 · Cited by 356
Self-citationNeumeister, A., Normandin, M. D., Pietrzak, R. H., Piomelli, D., Zheng, M. Q., Gujarro-Anton, A., Potenza, M. N., Bailey, C. R., Lin, S. F., Najafzadeh, S., et al. (2013) · Molecular Psychiatry · doi:10.1038/mp.2013.61 · Cited by 361
Self-citationResolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
Rahmim, A., Qi, J., & Sossi, V. (2013) · Medical Physics · doi:10.1118/1.4800806 · Cited by 357
PET/MRI for Neurologic Applications
Catana, C., Drzezga, A., Heiss, W.-D., & Rosen, B. R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.105346 · Cited by 288
Metadata
- Authors
- Carson, R. E., Barker, W. C., Liow, J.-S., & Johnson, C. A.
- Venue
- 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)
- Publisher
- IEEE
- Published
- 2004-11-15
- Pages
- 3281-3285
- ISSN
- 1095-7863 (ISSN-L)
- OpenAlex
- W2156876729
- Cited by
- 262
- References
- 7
- FWCI
- 21.99
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT. https://app.cochat.ai/papers/10.1109/nssmic.2003.1352597
- The paper
- Carson, R. E., Barker, W. C., Liow, J.-S., & Johnson, C. A. (2004). Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT. 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515). https://doi.org/10.1109/nssmic.2003.1352597
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.