Status of the high energy SC linac for the TRASCO program
Open accessAbstract
The status of the activities for the superconducting high energy linac of the TRASCO Program for an ADS system for nuclear waste transmutation is presented here. The design of a 1-2 GeV, 30 mA, linac at 704.4 MHz is briefly discussed. The results on the cavity prototypes of the low-/spl beta/ cavities (/spl beta/=0.5) are reported.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Laser Flash technique is based on measuring the thermal transient of the rear surface when a pulsed laser illuminates the front.
“The Laser Flash technique is based on the measure of the thermal transient of the rear surface of the sample when a pulsed laser illuminates the front”
From Thermal properties measurements using laser flash technique at cryogenic temperature (2002) · cites this paper as [6]
Section 2.4 describes RF testing and thermal mapping of superconducting cavities, while Section 2.5 reports cavity surface-resistance measurements; page numbers are unavailable in our copy. Searches for the Laser Flash technique and for pulsed-laser illumination followed by a rear-surface thermal transient found no passage addressing the claimed method. (LLM, conf=0.76)
Experimental — accuracy not yet measuredThe Laser Flash technique avoids interferences between the thermal sensor and the heat source.
“The Laser Flash technique is based on the measure of the thermal transient of the rear surface of the sample when a pulsed laser illuminates the front: in this way it is possible to avoid interferences between the thermal sensor and the heat source [6].”
From Thermal properties measurements using laser flash technique at cryogenic temperature (2002) · cites this paper as [6]
Section 2.4 describes RF measurements and thermal mapping of accelerator cavities, not the Laser Flash technique. Searches for Laser Flash, rear-surface thermal transients, and interference between a thermal sensor and heat source found no passage addressing the claim in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 8
- D. Barni, A. Bosotti, G. Ciovati, C. Pagani, P. Pierini, "SC Cavity Design For The 700 MHz TRASCO Linac", in Proceedings of the 2000 European Particle Accelerator Conference, Vienna, Austria, p. 2019.
- J.L. Biarrotte, H. Safa, J.P. Charrier, S. Jaidane, H. Gassot, T. Junquera, J. Lesrel, G. Ciovati, P. Pierini, D. Barni, C. Pagani, "704 MHz Superconducting Cavities For A High Intensity Proton Accelerator", in Proceedings of the Ninth Workshop on RF Superconductivity, Santa Fe, NM USA, 1999.
- H. Safa, "Superconducting Proton Linac for Waste Transmutation", in Proceedings of the Ninth Workshop on RF Superconductivity, Santa Fe, NM USA, 1999.
- P. Pierini, D. Barni, A. Bosotti, G. Ciovati, C. Pagani, "Cavity Design Tools And Applications To The TRASCO Project", in Proceedings of the Ninth Workshop on RF Superconductivity, Santa Fe, NM USA, 1999.
- D. Barni, C. Gesmundo, C. Pagani, G. Varisco, "Beta Tunable 700 MHz Insert With Natural Convection Precooling", in Proceedings of the Ninth Workshop on RF Superconductivity, Santa Fe, NM USA, 1999.
- B. Aune et al., "Superconducting TESLA Cavities", Phys. Rev. ST-AB, Vol. 3, 092001 (2000).
- W. Hartung et al, "Niobium Cavity Development for the High-Energy Linac of the Rare Isotope Accelerator", in these Proceedings.
- See "RF Superconductivity for Accelerators", by H. Padamsee, J. Knobloch, T. Hays, John Wiley, 1998.
Cited by
Sorted by citations
Thermal properties measurements using laser flash technique at cryogenic temperature
Penco, G., Barni, D., Michelato, P., & Pagani, C. (2002) · PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268) · doi:10.1109/pac.2001.986637 · Cited by 4 · see citing works
Self-citation
- Authors
- Pagani, C., Barni, D., Bellomo, G., Bosotti, A., Michelato, P., Paulon, R., Pierini, P., Sertore, D., & Varisco, G.
- Affiliations
- Istituto Nazionale di Fisica Nucleare (IT)
- Venue
- PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268)
- Publisher
- IEEE
- Published
- 2002-11-14
- Volume
- 5
- Pages
- 3612-3614
- OpenAlex
- W2130680623
- Cited by
- 6
- References
- 0
- FWCI
- 2.38
- Type
- conference paper
- Language
- en
- Open access
- green
- cds.cern.ch
- Locations
- Particle Accelerator Conference (PAC) (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Funders
- Institut National de Physique Nucléaire et de Physique des Particules
- Thomas Jefferson National Accelerator Facility
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Biomedical Engineering › Superconducting Materials and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Particle Accelerators and Free-Electron Lasers
- Keywords
- superconducting linear accelerator, accelerator-driven system, nuclear waste transmutation, low-beta cavities
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.