Multiple-output magnetic feedback forward converter with discrete PWM for space application
Abstract
This paper is aimed at design and development of fixed high frequency Forward Converter Topology operating at resonant reset mode for Space applications. This self-resonant reset mechanism eliminates power loss in the reset circuit, thus simplifying circuitry and increasing efficiency. The galvanic isolation between input and output is implemented with magnetic feedback which is insensitive to component tolerance, radiation and has good temperature stability. Due to unavailability of radiation hardened PWM IC at higher frequency (>500 KHz), discrete PWM controller has been implemented. Hence, magnetic feedback and discrete PWM controller meets the requirements of radiation for DC-DC Converter for space application. The proposed topology is demonstrated with an experimental prototype that delivers three outputs 5V/4A, ±15V/0.667A from an 18–50 V input with better than 75% at full efficiency.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A decentralized multi-output magnetic feedback forward converter for space applications is demonstrated in [74].
“A decentralized multi-output magnetic feedback forward converter for space applications is demonstrated in [74].”
From A Comprehensive Review on Small Satellite Microgrids (2022) · cites this paper as [74]
The converter in [74] is a galvanically isolated topology with a magnetic feedback system implemented instead of classic optocoupler feedback.
“This converter is a galvanically isolated topology, with a magnetic feedback system implemented instead of the classic optocoupler feedback, which is sensitive to radiation and temperature fluctuations.”
From A Comprehensive Review on Small Satellite Microgrids (2022) · cites this paper as [74]
The transformer-based converter in [74] enhances the topology with multiple output channels with minor additional circuitries.
“This transformer-based converter enhances the topology with multiple output channels, with some minor additional circuitries [74].”
From A Comprehensive Review on Small Satellite Microgrids (2022) · cites this paper as [74]
The converter in [74] has simpler circuitry compared to other multi-output converters and is more efficient because of the self-resonant reset mechanism.
“This converter has simpler circuitry compared to other multi-output converters and is more efficient because of the self-resonant reset mechanism.”
From A Comprehensive Review on Small Satellite Microgrids (2022) · cites this paper as [74]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 6 · Cited by 8
- Authors
- Rampelli, P. K., Deekshit, R., Reddy, D. S., Singh, B. K., Chippalkatti, V., & Kanthimathinathan, T.
- Affiliations
- B.M.S. College of Engineering (IN)
- Bengaluru City University (IN)
- Venue
- 2012 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES)
- Publisher
- IEEE
- Published
- 2012-12
- Pages
- 1-6
- OpenAlex
- W2546486327
- Cited by
- 8
- References
- 6
- Citations by year
- 2025: 2 · 2024: 1 · 2022: 2 · 2019: 1 · 2018: 1 · 2014: 1
- FWCI
- 0.41
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Conference on Power Electronics, Drives and Energy Systems (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
- Keywords
- forward converter, magnetic feedback, DC-DC converter, space power systems, radiation hardening, galvanic isolation, multiple output power supply, high switching frequency, converter efficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review