The DOI matches its Crossref record.
Advanced grid requirements for the integration of wind turbines into the German transmission system
Abstract
In Germany 18 GW wind power will have been installed by the end of 2005. Until 2020, this figure reaches the 50 GW mark. Based on the results of recent studies and on the experience with existing wind projects modification of the existing grid code for connection and operation of wind farms in the high voltage grid is necessary. The paper discusses main issues of the suggested requirements by highlighting major changes and extensions. The topics considered are fault ride-through, grid voltage maintenance respective voltage control, system monitoring and protection as well as retrofitting of old units. The new requirements are defined taking into account some new developments in wind turbine technologies which should be utilized in the future to meet grid requirement. Monitoring and system protection is defined under the aspect of sustainability of the measures introduced
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review of grid code technical requirements for wind farms
Tsili, M., & Papathanassiou, S. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2008.0070 · Cited by 1,373
Overview of different wind generator systems and their comparisons
Li, H., & Chen, Z. (2008) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20070044 · Cited by 987
Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
Alepuz, S., Busquets-Monge, S., Bordonau, J., Martinez-Velasco, J. A., Silva, C. A., Pontt, J., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017102 · Cited by 373
Abu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
“As an example, FRT requirements according to German grid code E.ON Netz [88] are classified depending on the severity of fault.”
BackgroundInfluential
Metadata
- Authors
- Erlich, I., Winter, W., & Dittrich, A.
- Venue
- 2006 IEEE Power Engineering Society General Meeting
- Publisher
- IEEE
- Published
- 2006
- Pages
- 7 pp.
- ISSN
- 1932-5517 (ISSN-L)
- OpenAlex
- W1974773897
- Cited by
- 246
- References
- 0
- FWCI
- 33.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advanced grid requirements for the integration of wind turbines into the German transmission system. https://app.cochat.ai/papers/10.1109/pes.2006.1709340
- The paper
- Erlich, I., Winter, W., & Dittrich, A. (2006). Advanced grid requirements for the integration of wind turbines into the German transmission system. 2006 IEEE Power Engineering Society General Meeting. https://doi.org/10.1109/pes.2006.1709340
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.