An average model of solid state transformer for dynamic system simulation
The DOI matches its Crossref record.
Abstract
The solid state transformer (SST) is one of the key elements proposed in the National Science Foundation (NSF) Generation-III Engineering Research Center (ERC) ldquoFuture Renewable Electric Energy Delivery and Managementrdquo (FREEDM) Systems Center established in 2008. The SST is used to enable active management of distributed renewable energy resources, energy storage devices and loads. In this paper, a 20 kVA solid state transformer based on 6.5 kV IGBT is proposed for interface with 12 kV distribution system voltage. The average model and control scheme of SST including AC/DC rectifier, dual active bridge (DAB) converter and DC/AC inverter are developed to enable dynamic system level simulation. The developed average model is verified by comparing with the detailed switching model simulation. The dynamic system level SST simulation verifies the proposed controller and the corresponding average model illustrates the functionalities and advantages of the SST in FREEDM system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642
“The SST has the features of instantaneous voltage regulation, voltage sag compensation, fault isolation, power factor correction, harmonic isolation, and dc output [1]–[4].”
BackgroundSelf-citationGao, R., She, X., Husain, I., & Huang, A. Q. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2679679 · Cited by 76
“The modeling of the studied SST that consists of VSR, DAB, and voltage-source inverter (VSI) stages appears in [26].”
MethodSelf-citationNew Bidirectional Intelligent Semiconductor Transformer for Smart Grid Application
Han, B.-M., Choi, N.-S., & Lee, J.-Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2284009 · Cited by 37
Zhao, H., Zhu, T., Cheng, D., Li, B., Ding, J., & Li, Y. (2017) · The Journal of Engineering · doi:10.1049/joe.2017.0656 · Cited by 19
Metadata
- Authors
- Zhao, T., Zeng, J., Bhattacharya, S., Baran, M. E., & Huang, A. Q.
- Venue
- 2009 IEEE Power & Energy Society General Meeting
- Publisher
- IEEE
- Published
- 2009-07
- Pages
- 1-8
- OpenAlex
- W2136700375
- Cited by
- 138
- References
- 0
- FWCI
- 12.00
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An average model of solid state transformer for dynamic system simulation. https://app.cochat.ai/papers/10.1109/pes.2009.5275542
- The paper
- Zhao, T., Zeng, J., Bhattacharya, S., Baran, M. E., & Huang, A. Q. (2009). An average model of solid state transformer for dynamic system simulation. 2009 IEEE Power & Energy Society General Meeting. https://doi.org/10.1109/pes.2009.5275542
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.