A three-phase AC/AC high-frequency link matrix converter for VSCF applications
The DOI matches its Crossref record.
Abstract
In this paper, a new three-phase high-frequency link matrix converter is discussed and the topology of conventional matrix converter is modified with the addition of a transformer for a variable speed constant frequency (VSCF) application. The proposed approach accomplishes voltage transfer ratio more than unity, galvanic isolation between both voltage sources and higher power density by employing a high-frequency transformer into the intermediate stage of the dual bridge matrix converter. It has a bidirectional power flow capability, controllable displacement power factor and lower harmonic distortion at both variable speed source and fixed frequency utility. Further, asynchronous or synchronous PWM can be employed depending on the frequency modulation ratio in the primary side converter and it guarantees full input voltage utilization for DC-link and near symmetric square wave pulse trains applied to high frequency transformer regardless of varying input frequency. The proposed approach is a competitive solution for VSCF distributed generating application such as wind-turbine and micro-turbine application. Simulation results are shown to demonstrate the advantages of the proposed system. Experimental results on a 230V, 3kVA 400 Hz to 60 Hz VSCF system based on DSP controller are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nehrir, M. H., Wang, C., Strunz, K., Aki, H., Ramakumar, R., Bing, J., Miao, Z., & Salameh, Z. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2157540 · Cited by 928
A review on configurations, control and sizing methodologies of hybrid energy systems
Upadhyay, S., & Sharma, M. P. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.057 · Cited by 371
Topology comparison for Solid State Transformer implementation
Falcones, S., Mao, X., & Ayyanar, R. (2010) · IEEE PES General Meeting · doi:10.1109/pes.2010.5590086 · Cited by 283
Abu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
“A two stage matrix-based SST was presented in [21] for a variable speed constant frequency generator.”
BackgroundMethodInfluentialA new matrix type three-phase four-wire power electronic transformer
Ai-juan, J., Hang-tian, L., & Shao-long, L. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711919 · Cited by 16
Metadata
- Authors
- Cha, H. J., & Enjeti, P. N.
- Venue
- IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03.
- Publisher
- IEEE
- Published
- 2004-03-02
- Volume
- 4
- Pages
- 1971-1976
- OpenAlex
- W1938625929
- Cited by
- 110
- References
- 0
- FWCI
- 7.04
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A three-phase AC/AC high-frequency link matrix converter for VSCF applications. https://app.cochat.ai/papers/10.1109/pesc.2003.1217754
- The paper
- Cha, H. J., & Enjeti, P. N. (2004). A three-phase AC/AC high-frequency link matrix converter for VSCF applications. IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03. https://doi.org/10.1109/pesc.2003.1217754
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.