An Efficient Machine Learning Model for Microgrid Fault Detection and Classification: Protection Approach
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The protection system is an important component of microgrid operation and stability. The protection system must be capable of identifying faults, isolating the faulty sections, and ensuring continuity of the power supply to unaffected loads. The objective of this paper is to develop an efficient machine-learning fault detection and classification protection device capable of detecting low and high-impedance faults in AC microgrids. The protection device shall be adaptive to microgrid topology changes, bidirectional power flow, fault current levels, renewable energy resources faults infeed, stable under normal conditions, and fast tripping for low and high impedance faults. The protection device is a hybrid deep CNN-GRU-directional relay model. The paper adopts a protection approach for accuracy, stability against reverse direction faults, and noise immunity when evaluating this efficient model along with other machine learning models using MATLAB.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Ensemble methods in machine learning
Dietterich, T. G. (2000) · Lecture Notes in Computer Science · doi:10.1007/3-540-45014-9_1 · Cited by 8,408
Ensemble Methods: Foundations and Algorithms
Zhou, Z.-H. (2012) · doi:10.1201/b12207 · Cited by 2,534
Intelligent Fault Detection Scheme for Microgrids With Wavelet-Based Deep Neural Networks
Yu, J. J. Q., Hou, Y., Lam, A. Y. S., & Li, V. O. K. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2776310 · Cited by 451
Adaptive protection combined with machine learning for microgrids
Lin, H., Sun, K., Tan, Z., Liu, C., Guerrero, J. M., & Vasquez, J. C. (2019) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2018.6230 · Cited by 189
Choudhury, S. (2020) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12446 · Cited by 139
Recent Developments and Challenges on AC Microgrids Fault Detection and Protection Systems–A Review
Hussain, N., Nasir, M., Vásquez, J. C., & Guerrero, J. M. (2020) · Energies · doi:10.3390/en13092149 · Cited by 114
Azizi, R., & Şeker, S. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3109023 · Cited by 62
Li, Z., Hu, J., & Chan, K. W. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3104269 · Cited by 48
Research works printed but not linked: 1
- Strunz, 2014, TF C6.04.02: TB 575 - Benchmark Systems for Network Integration of Renewable and Distributed Energy Resources, 04
Cited by
Oelhaf, J., Kordowich, G., Pashaei, M., Bergler, C., Maier, A., Jaeger, J., & Bayer, S. (2025) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.111257 · Cited by 60
“…such as DWT and multi-resolution analysis are widely used for feature extraction [117, 118], while classifiers range from conventional models (SVM, DT, NB) to advanced architectures, including CNNs, hybrid CNN-GRU [119], and both centralized and communication-free ANN-based schemes [120, 121].”
Exploring the efficacy of GRU model in classifying the signal to noise ratio of microgrid model
Alsulami, A. A., Al-Haija, Q. S. A., Alturki, B., Alqahtani, A., Binzagr, F., Alghamdi, B. M., & Alsemmeari, R. A. (2024) · Scientific Reports · doi:10.1038/s41598-024-66387-1 · Cited by 22
“54 , authors proposed a hybrid GRU-CNN-directional architecture to detect the faults in AC microgrid.”
BackgroundSharma, S., Shenoy, A., & Manitha, P. V. (2024) · International Conference on Communication and Electronics Systems (ICCES) · doi:10.1109/icces63552.2024.10860003 · Cited by 4
“Thus, with ML, such scenarios might be envisioned in advance of the disturbances occurring [5,6].”
Review of Fault Detection Methods in Microgrids: From Conventional to Innovative Perspective
Hasır, M., Akpolat, A. N., & Ayan, K. (2026) · IET Renewable Power Generation · doi:10.1049/rpg2.70171
Metadata
- Authors
- AlSaba, M., & Abido, M.
- Affiliations
- King Fahd University of Petroleum and Minerals (SA)
- ORCID
- Abido, Mohammad
- Venue
- 2023 IEEE Power & Energy Society General Meeting (PESGM)
- Publisher
- IEEE
- Published
- 2023-07-16
- Pages
- 1-5
- ISSN
- 1932-5517 (ISSN-L)
- OpenAlex
- W4387027421
- Semantic Scholar
- 0ecd47eeaccf23506edb8a86ab6678d03aef4641
- Cited by
- 7
- References
- 14
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 2
- FWCI
- 3.00
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Power Engineering Society General Meeting (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical Fault Detection and Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Keywords
- microgrid protection, fault detection, fault classification, low impedance faults, high impedance faults, directional relays, CNN-GRU hybrid model, bidirectional power flow, adaptive protection, noise immunity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Efficient Machine Learning Model for Microgrid Fault Detection and Classification: Protection Approach. https://app.cochat.ai/papers/10.1109/pesgm52003.2023.10252224
- The paper
- AlSaba, M., & Abido, M. (2023). An Efficient Machine Learning Model for Microgrid Fault Detection and Classification: Protection Approach. 2023 IEEE Power & Energy Society General Meeting (PESGM). https://doi.org/10.1109/pesgm52003.2023.10252224
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.