The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A grid simulator with control of single-phase power converters in D-Q rotating frame
Abstract
A control method in the direct-quadrature (DQ) rotating frame for a single-phase inverter or PFC rectifier is proposed to provide an infinite control gain (theoretically), thus zero steady state error at its fundamental frequency to achieve superior steady state and dynamic performance. This new control method transforms the physical "real circuit", in conjunction with an "imaginary orthogonal circuit", from the stationary frame to the DQ rotating frame so that the steady state voltage/current in the DQ frame become DC variables. The new control concept is validated through a single-phase grid simulator used for utility compatibility tests, as described in IEEE P1547 draft standard, IEEE Std 929, UL 1741 and NYSIR, for single-phase distributed generators (DG), such as residential fuel cell generators or photovoltaic power conditioning systems. Experimental results in steady state with programmable simulated utility line impedance are given along with the dynamic transient response for NYSIR type test. The control concept is also applicable to zero-sequence control for three-phase four-wire systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 815
Yuan, X., Allmeling, J., Merk, W., & Stemmler, H. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883122 · Cited by 663
Control topology options for single-phase UPS inverters
Ryan, M. J., Brumsickle, W. E., & Lorenz, R. D. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568015 · Cited by 429
Cited by
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642
“The single-phase dq transformation is applied to the (5) and (6) [14], and the differential equations in dq coordinates are Fig.”
MethodDesign of Parallel Inverters for Smooth Mode Transfer Microgrid Applications
Chen, C.-L., Wang, Y., Lai, J.-S., Lee, Y.-S., & Martin, D. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2025864 · Cited by 382
Dynamics Assessment of Advanced Single-Phase PLL Structures
Golestan, S., Monfared, M., Freijedo, F. D., & Guerrero, J. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2193863 · Cited by 371
(2013) · Cited by 39
Metadata
- Authors
- Zhang, R., Cardinal, M., Szczesny, P., & Dame, M.
- Venue
- 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289)
- Publisher
- IEEE
- Published
- 2003-06-25
- Pages
- 1431-1436
- OpenAlex
- W2158420518
- Cited by
- 281
- References
- 4
- FWCI
- 6.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.