Assessment of the hosting capacity in distribution networks with different DG location
Abstract
The increasing penetration of distributed generation (DG) could cause positive and adverse impacts on distribution power grids. The study of these effects could lead to methodological guidelines for sizing and location of renewable energy sources. In this paper several simulations of a distibution system of MV with different locations and penetration levels of DG are performed. Performance parameters as transmission capacity and voltage level are calculated and the impact of the different penetration scenarios is assessed. Finally a relationship among benefits, the Hosting Capacity (HC), and the distance between feeder-head and DG location is characterized. A new index is proposed to value the better location of units and generation power based on this relationship.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The location of PV is the major limiting factor of HC.
“The study presents the location of PV as the major limiting factor of HC and proposes an index to quantify the impact of the location of PV units.”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [57]
The deterministic HC method is effective for performing sensitivity analysis of solar PV integration into LV distribution networks.
“Additionally, the deterministic HC method is found to be effective for performing sensitivity analysis of solar PV integration into the LV distribution networks similar to results obtained in [56,57].”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [57]
Cited by
Sorted by citations
Umoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71 · see citing works
- Authors
- Quintero-Molina, V., Romero-L, M., & Pavas, A.
- Affiliations
- Universidad Nacional de Colombia (CO)
- ORCID
- Quintero-Molina, V.
- Venue
- 2017 IEEE Manchester PowerTech
- Publisher
- IEEE
- Published
- 2017-06
- Pages
- 1-6
- OpenAlex
- W2737375615
- Cited by
- 19
- References
- 0
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 3 · 2018: 3
- FWCI
- 3.48
- Type
- conference paper
- Language
- en
- Open access
- closed
- Funders
- Departamento Administrativo de Ciencia, Tecnología e Innovación (COLCIENCIAS)
- Universidad Nacional de Colombia
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Control and Systems Engineering › Thermal Analysis in Power Transmission
- Keywords
- hosting capacity, distributed generation, distribution networks, DG penetration level, transmission capacity, voltage levels, medium-voltage feeders, location index
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review