The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Comparative study of maximum power point tracking algorithms using an experimental, programmable, maximum power point tracking test bed
Abstract
Maximum power point tracking (MPPT) is important in solar power systems because it reduces the solar array cost by decreasing the number of solar panels needed to obtain the desired output power. Several different MPPT methods have been proposed, but there has been no comprehensive experimental comparison between all the different algorithms and their overall maximum power point (MPP) tracking efficiencies under varying conditions (i.e. Illumination, temperature, and load). This paper such a comparison. Results are using a microprocessor controlled MPPT powered by a 250 W photovoltaic (PV) array and also a PV array simulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum photovoltaic power tracking: an algorithm for rapidly changing atmospheric conditions
Hussein, K. H. (1995) · IEE Proceedings - Generation, Transmission and Distribution · doi:10.1049/ip-gtd:19951577 · Cited by 1,764
Implementation of a DSP-controlled photovoltaic system with peak power tracking
Hua, C., Lin, J., & Shen, C. (1998) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.661310 · Cited by 706
New approach to photovoltaic arrays maximum power point tracking
Brambilla, A., Gambarara, M., Garutti, A., & Ronchi, F. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1999.785575 · Cited by 156
Cited by
Optimization of Perturb and Observe Maximum Power Point Tracking Method
Femia, N., Petrone, G., Spagnuolo, G., & Vitelli, M. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.850975 · Cited by 3,002
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Solar power generation by PV (photovoltaic) technology: A review
Singh, G. K. (2013) · Energy · doi:10.1016/j.energy.2013.02.057 · Cited by 1,123
On the Perturb-and-Observe and Incremental Conductance MPPT Methods for PV Systems
Sera, D., Mathe, L., Kerekes, T., Spataru, S. V., & Teodorescu, R. (2013) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2013.2261118 · Cited by 823
Reza Reisi, A., Hassan Moradi, M., & Jamasb, S. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.11.052 · Cited by 690
Adaptive perturb and observe algorithm for photovoltaic maximum power point tracking
Piegari, L., & Rizzo, R. (2010) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2009.0006 · Cited by 435
A comprehensive comparison of different MPPT techniques for photovoltaic systems
Rezk, H., & Eltamaly, A. M. (2015) · Solar Energy · doi:10.1016/j.solener.2014.11.010 · Cited by 435
Predictive & Adaptive MPPT Perturb and Observe Method
Femia, N., Granozio, D., Petrone, G., Spagnuolo, G., & Vitelli, M. (2007) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2007.4383584 · Cited by 406
Modeling and Control of Three-Port DC/DC Converter Interface for Satellite Applications
Qian, Z., Abdel-Rahman, O., Al-Atrash, H., & Batarseh, I. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033926 · Cited by 399
“The reference is provided by an MPPT controller [29] using perturb and observe algorithm, and represents an estimate of the optimal operating voltage, duty cycle d2 is used as the control input when realizing the IVR loop.”
MethodJiang, L. L., Maskell, D. L., & Patra, J. C. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.06.004 · Cited by 282
Low-Power Far-Field Wireless Powering for Wireless Sensors
Popovic, Z., Falkenstein, E. A., Costinett, D., & Zane, R. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2244053 · Cited by 255
Incorporating battery energy storage systems into multi-MW grid connected PV systems
Rallabandi, V., Akeyo, O. M., Jewell, N., & Ionel, D. M. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2864696 · Cited by 115
Metadata
- Authors
- Hohm, D. P., & Ropp, M. E.
- Venue
- Conference Record of the Twenty-Eighth IEEE Photovoltaic Specialists Conference - 2000 (Cat. No.00CH37036)
- Publisher
- IEEE
- Published
- 2002-11-11
- Pages
- 1699-1702
- ISSN
- 0160-8371 (ISSN-L)
- OpenAlex
- W2159027549
- Cited by
- 576
- References
- 3
- FWCI
- 15.90
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.